Effect of decrease in heart rate variability on the diagnostic accuracy of 64-MDCT coronary angiography

被引:55
作者
Leschka, Sebastian [1 ]
Scheffel, Hans [1 ]
Husmann, Lars [2 ]
Gaemperli, Oliver [2 ]
Marincek, Borut [1 ]
Kaufmann, Philipp A. [2 ,3 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Dept Med Radiol, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
64-MDCT; coronary angiography; coronary artery disease; heart rate;
D O I
10.2214/AJR.07.2000
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of average heart rate and heart rate variability on the diagnostic accuracy of 64-MDCT in the assessment of coronary artery stenosis. SUBJECTS AND METHODS. CT and invasive coronary angiography were performed on 114 patients (mean age, 62 years) referred for known coronary artery disease (n = 26), atypical chest pain (n = 58), and presurgical exclusion of coronary artery disease before abdominal aortic (n = 14) or cardiac valve (n = 16) surgery. The population was divided into two groups depending on median average heart rate (60.0 beats/min) and median heart rate variability (2.7 beats/ min) during scanning. Heart rate variability was calculated as SD from the mean heart rate. Two blinded observers using a 4-point scale independently assessed the quality of images of each coronary artery segment and classified each segment as being stenosed (luminal diameter narrowing > 50%) or not. Invasive coronary angiography was used as the reference standard. RESULTS. In 71 (62.3%) of the patients, 241 significant coronary artery stenoses were identified with invasive coronary angiography. In 11 (9.7%) of the patients, 1.6% (26/ 1,672) of the segments were not evaluable with CT. Overall sensitivity, specificity, and positive and negative predictive values in a patient-based analysis were 97%, 81%, 90%, and 95%, respectively. Image quality was better (p < 0.05) in the low average heart rate group than in the high average heart rate group, but diagnostic accuracy was comparable for the two groups. In contrast, image quality and diagnostic accuracy were significantly better (p < 0.01) among patients in the low heart rate variability group than in the high heart rate variability group. CONCLUSION. Lower heart rate variability is associated with higher diagnostic accuracy of 64-MDCT coronary angiography.
引用
收藏
页码:1583 / 1590
页数:8
相关论文
共 29 条
[1]  
Austen W G, 1975, Circulation, V51, P5
[2]   Quantitative assessment of of in-stent dimensions: A comparison of 64 and 16 detector multislice computed tomography to intravascular ultrasound [J].
Beohar, Nirat ;
Robbins, Joel D. ;
Cavanaugh, Brendan J. ;
Ansari, Asimul H. ;
Yaghmai, Vahid ;
Carr, James ;
Davidson, Charles J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :8-10
[3]   Non-invasive coronary angiography with 16-slice spiral computed tomography:: image quality in patients with high heart rates [J].
Brodoefel, H ;
Reimann, A ;
Heuschmid, M ;
Küttner, A ;
Beck, T ;
Burgstahler, C ;
Claussen, CD ;
Schroeder, S ;
Kopp, AF .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1434-1441
[4]  
CADEMARTIRI F, 2006, AJR, V187, P1115
[5]  
Cademartiri Filippo, 2006, AJR Am J Roentgenol, V187, pW430, DOI 10.2214/AJR.05.1406
[6]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[7]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[8]  
Halliburton SS, 2003, HERZ, V28, P20, DOI 10.1007/s00059-003-2445-4
[9]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[10]   Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality [J].
Herzog, C ;
Abolmaali, N ;
Balzer, JO ;
Baunach, S ;
Ackermann, H ;
Dogan, S ;
Britten, MB ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2670-2678