A Comparison of Two Implant Systems in Restoration of Hip Geometry in Arthroplasty

被引:40
作者
Archibeck, Michael J. [1 ]
Cummins, Tamara [1 ]
Carothers, Joshua [1 ]
Junick, Daniel W. [1 ]
White, Richard E., Jr. [1 ]
机构
[1] New Mexico Orthopaed, New Mexico Ctr Joint Replacement Surg, Albuquerque, NM 87106 USA
关键词
LEG LENGTH DISCREPANCY; IMPINGEMENT;
D O I
10.1007/s11999-010-1678-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background Restoration of hip offset and leg length during THA is often limited by available implant geometries. The recent introduction of femoral components with a modular junction at the base of the neck (two modular junction components) has expanded the options to restore femoral offset and leg length. Questions/purposes We asked (1) whether a femoral component with two modular junctions would predict by templating more frequent restoration of preoperative offset and leg length abnormalities than one with single modular junctions; and (2) how our use of these options compared with national sales data. Patients and Methods We retrospectively reviewed the preoperative templating data in 100 primary THAs using single modular junction implants with only a neutral version stem and 100 THAs using two modular junction implants. We compared the frequency with which the desired leg length and offset were completely restored by preoperative templating in the two groups. Results Offset and leg lengths were restored to within 1 mm in 85% of cases with two modular junction implants and 60% of cases with single modular junction implants. An anteverted or a retroverted neck was used in 25% of cases with the two modular junction stems. The national sales data revealed femoral neck components with version were used in 28% of cases. Conclusions The use of a femoral component with two modular junctions resulted in more frequent ability to restore femoral offset and leg length than a single modular junction. The advantage of clinical flexibility should be tempered by the potential concerns of prosthetic mechanical failure (which has been reported in another implant system with two modular junctions), increased third-body wear and corrosive debris, and increased prosthetic cost.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 14 条
[1]
Stability and leg length equality in total hip arthroplasty [J].
Austin, MS ;
Hozack, WJ ;
Sharkey, PF ;
Rothman, RH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :88-90
[2]
Soft tissue balancing - The hip [J].
Bourne, RB ;
Rorabeck, CH .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :17-22
[3]
Preoperative Planning and Reconstruction in Primary Total Hip Arthroplasty with and without Modular Necks [J].
Heep, H. ;
Wegner, A. ;
Xu, J. ;
Kauther, M. ;
Loeer, F. A. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2010, 148 (02) :180-184
[4]
Lateral trochanteric pain following primary total hip arthroplasty [J].
Iorio, R ;
Healy, WL ;
Warren, PD ;
Appleby, D .
JOURNAL OF ARTHROPLASTY, 2006, 21 (02) :233-236
[5]
The importance of leg length discrepancy after total hip arthroplasty [J].
Konyves, A ;
Bannister, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :155-157
[6]
Impingement with total hip replacement [J].
Malik, Aamer ;
Maheshwari, Aditya ;
Dorr, Lawrence D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08) :1832-1842
[7]
Leg length discrepancy after total hip arthroplasty [J].
Maloney, WJ ;
Keeney, JA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :108-110
[8]
Maruyama M, 2001, CLIN ORTHOP RELAT R, P52
[9]
Effect of anesthesia type on limb length discrepancy after total hip arthroplasty [J].
Sathappan, Sathappan S. ;
Ginat, Daniel ;
Patel, Vipul ;
Walsh, Michael ;
Jaffe, William L. ;
Di Cesare, Paul E. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (02) :203-209
[10]
Impingement in total hip arthroplasty - A study of retrieved acetabular components [J].
Shon, WY ;
Baldini, T ;
Peterson, MG ;
Wright, TM ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2005, 20 (04) :427-435