The long-term within- and between-laboratory variability for assay of antithrombin, and proteins C and S: results derived from the external quality assessment program for thrombophilia screening of the ECAT Foundation

被引:34
作者
Meijer, P
Kluft, C
Haverkate, F
De Maat, MPM
机构
[1] ECAT Fdn, NL-2301 CE Leiden, Netherlands
[2] TNO Prevent & Hlth, Gaubius Lab, Leiden, Netherlands
关键词
analytical performance; external quality assessment; hemostasis;
D O I
10.1046/j.1538-7836.2003.00141.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A stable laboratory performance is important for comparability and transferability of laboratory data both within and between laboratories. The lack of a reference system within hemostasis hampers laboratories in establishing their laboratory performance over a prolonged period of time. Therefore, based on data from an external quality assessment program, we evaluated the between laboratory variation (CVBETWEEN) and the long-term within-laboratory variation (LCVa) for antithrombin, and proteins C and S. We evaluated the CVBETWEEN for the period 1996-2001, including the results of 64-240 laboratories from 23 different surveys (protein S activity 15 surveys). We observed a quite high CVBETWEEN and a broad range for each analyte. The CVBETWEEN was significantly higher for antithrombin and protein S for samples with low levels similar to heterozygous deficiencies. We also evaluated the LCVa, including the results of 136 laboratories. The lowest LCVa [median and 95% content interval (Cl)] was observed for antithrombin (7.6%; 3.6-35.5%), intermediate values for protein C activity and antigen (8.6%; 3.5-25.3% and 10.8%; 4.8-33.1%, respectively) and highest values for the protein S variables (13.4%; 6.4-50.6% for total protein S antigen, 14.1%; 6.5-79.1% for free protein S antigen and 17.2%; 7.2-84.3% for protein S activity). We concluded that the main reason for the high CVBETWEEN is the long-term within-laboratory variability. Application of linear regression on data of an external quality assessment program is a useful model to demonstrate per analyte per laboratory the long-term variability (LCVa). It is concluded that improvement of the long-term within-laboratory test performance is the first priority in hemostasis to yield important improvements in the comparability and transferability of laboratory data.
引用
收藏
页码:748 / 753
页数:6
相关论文
共 22 条
[1]  
BERTINA RM, 1982, THROMB HAEMOSTASIS, V48, P1
[2]  
BROCKMANS AW, 1983, NEW ENGL J MED, V309, P340
[3]  
BUTTNER J, 1994, EUR J CLIN CHEM CLIN, V32, P571
[4]   FAMILIAL PROTEIN S DEFICIENCY IS ASSOCIATED WITH RECURRENT THROMBOSIS [J].
COMP, PC ;
NIXON, RR ;
COOPER, MR ;
ESMON, CT .
JOURNAL OF CLINICAL INVESTIGATION, 1984, 74 (06) :2082-2088
[5]   The evolution and limitations of accuracy and precision standards [J].
Doumas, BT .
CLINICA CHIMICA ACTA, 1997, 260 (02) :145-162
[6]   INHERITED ANTITHROMBIN DEFICIENCY CAUSING THROMBOPHILIA [J].
EGEBERG, O .
THROMBOSIS ET DIATHESIS HAEMORRHAGICA, 1965, 13 (3-4) :516-&
[7]  
EHRMEYER SS, 1985, CLIN CHEM, V31, P106
[8]  
FRASER CG, 1993, CLIN CHEM, V39, P1447
[9]  
Gram J, 1999, FIBRINOLYSIS PROTEOL, V13, P30
[10]   DEFICIENCY OF PROTEIN-C IN CONGENITAL THROMBOTIC DISEASE [J].
GRIFFIN, JH ;
EVATT, B ;
ZIMMERMAN, TS ;
KLEISS, AJ ;
WIDEMAN, C .
JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (05) :1370-1373