Quantitative lateral flow immunosensor using carbon nanotubes as label

被引:32
作者
Abera, Adeyabeba [1 ]
Choi, Jin-Woo [1 ]
机构
[1] Louisiana State Univ, Dept Elect & Comp Engn, Baton Rouge, LA 70803 USA
基金
美国国家科学基金会;
关键词
FUNCTIONALIZATION; ASSAYS;
D O I
10.1039/c0ay00412j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel immunosensor utilizing multi-walled carbon nanotube as label on a lateral flow system for simple and quantitative electrical detection was investigated. Multi-walled carbon nanotubes (MWCNTs) were first modified with polyvinylpyrrolidone (PVP) for uniform dispersion in aqueous solution. Then, the MWCNTs were conjugated with human immunoglobulin G (IgG) using 1-(3-(dimethylamino)-propy1)-3-ethylcarbodiimide hydrochloride (EDC) coupling chemistry. The lateral flow immunosensor was made of nitrocellulose membrane that transports sample and reagents through a porous structure by capillary action. The performance of the immunosensor was demonstrated using human IgG as a model analyte competing with the conjugate (MWCNT-labeled human IgG) at the capture zone. As a result of binding reaction between the conjugate and the immobilized Protein A at the capture zone, the conjugated MWCNTs formed a conducting network at the capture zone providing conductance measurement corresponding to the amount of captured conjugate. Quantitative immunoassay response for the target human IgG was demonstrated in the range of 25 to 200 mu g ml(-1) without an additional amplification step. The presented immunosensing technique could be expanded for the detection of various analyte-specific biomolecules with a potential for simple and rapid tests suitable for point-of-care diagnostics.
引用
收藏
页码:1819 / 1822
页数:4
相关论文
共 17 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Molecular electronics with carbon nanotubes [J].
Avouris, P .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (12) :1026-1034
[3]   Rapid, sensitive, and specific lateral-flow immunochromatographic device to measure anti-anthrax protective antigen immunoglobulin G in serum and whole blood [J].
Biagini, Raymond E. ;
Sammons, Deborah L. ;
Smith, Jerome P. ;
MacKenzie, Barbara A. ;
Striley, Cynthia A. F. ;
Snawder, John E. ;
Robertson, Shirley A. ;
Quinn, Conrad P. .
CLINICAL AND VACCINE IMMUNOLOGY, 2006, 13 (05) :541-546
[4]   Single-electron transport in ropes of carbon nanotubes [J].
Bockrath, M ;
Cobden, DH ;
McEuen, PL ;
Chopra, NG ;
Zettl, A ;
Thess, A ;
Smalley, RE .
SCIENCE, 1997, 275 (5308) :1922-1925
[5]   Simple and fast lateral flow test for classification of leprosy patients and identification of contacts with high risk of developing leprosy [J].
Bührer-Sékula, S ;
Smits, HL ;
Gussenhoven, GC ;
van Leeuwen, J ;
Amador, S ;
Fujiwara, T ;
Klatser, PR ;
Oskam, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) :1991-1995
[6]   Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization [J].
Chen, RJ ;
Zhang, YG ;
Wang, DW ;
Dai, HJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (16) :3838-3839
[7]  
Clark T.J., 2002, POINT CARE, V1, P42
[8]  
Corstjens P, 2001, CLIN CHEM, V47, P1885
[9]  
Fernández-Sánchez C, 2004, ELECTROCHEM COMMUN, V6, P138, DOI 10.1016/j.elecom.11.002
[10]  
Hirsch A, 2002, ANGEW CHEM INT EDIT, V41, P1853, DOI 10.1002/1521-3773(20020603)41:11<1853::AID-ANIE1853>3.0.CO