The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine

被引:216
作者
Lindsey, DP
Swanson, KE
Fuchs, P
Hsu, KY
Zucherman, JF
Yerby, SA
机构
[1] VA Rehab R&D Ctr, Palo Alto, CA USA
[2] San Francisco Orthopaed Residency Program, San Francisco, CA USA
[3] St Marys Spine Ctr, San Francisco, CA USA
[4] St Francis Med Technol, Concord, CA USA
关键词
spinal stenosis; neurogenic intermittent claudication; interspinous implant; kinematics;
D O I
10.1097/01.BRS.0000084877.88192.8E
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Measurement of the kinematics of the lumbar spine after insertion of an interspinous spacer in vitro. Objectives. To understand the kinematics of the instrumented and adjacent levels due to the insertion of this interspinous implant. Summary of Background Data. An interspinous spacer ( X Stop, SFMT, Concord, California) has been developed to treat neurogenic intermittent claudication by placing the stenotic segment in slight flexion and preventing extension. This restriction of motion by the interspinous implant may affect the kinematics of levels adjacent to the instrumented level. Methods. Seven lumbar spines (L2 - L5) were tested in flexion - extension, lateral bending, and axial rotation. Images were taken during each test to determine the kinematics of each motion segment. The interspinous implant was placed at the L3 - L4 level, and the test protocol was repeated. Results. The flexion - extension range of motion was significantly reduced at the instrumented level. Axial rotation and lateral bending ranges of motion were not affected at the instrumented level. The range of motion in flexion - extension, axial rotation, and lateral bending at the adjacent segments was not significantly affected by the implant. Conclusions. The implant does not significantly alter the kinematics of the motion segments adjacent to the instrumented level.
引用
收藏
页码:2192 / 2197
页数:6
相关论文
共 27 条
[1]
Arbit E, 2001, CLIN ORTHOP RELAT R, P137
[2]
NATURAL-HISTORY OF INTERMITTENT CLAUDICATION OF CAUDA-EQUINA - LONG-TERM FOLLOW-UP-STUDY [J].
BLAU, JN ;
LOGUE, V .
BRAIN, 1978, 101 (JUN) :211-222
[3]
Chen CS, 2001, MED ENG PHYS, V23, P483
[4]
Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments [J].
Chow, DHK ;
Luk, KDK ;
Evans, JH ;
Leong, JCY .
SPINE, 1996, 21 (05) :549-555
[5]
DVORAK J, 1991, SPINE, V16, P562
[6]
BICYCLE-TEST OF VANGELDEREN IN DIAGNOSIS OF INTERMITTENT CAUDA-EQUINA COMPRESSION SYNDROME - CASE-REPORT [J].
DYCK, P ;
DOYLE, JB .
JOURNAL OF NEUROSURGERY, 1977, 46 (05) :667-670
[7]
LUMBAR NERVE ROOT COMPRESSION AT INTERVERTEBRAL FORAMINA CAUSED BY ARTHRITIS OF POSTERIOR FACETS [J].
EPSTEIN, JA ;
EPSTEIN, BS ;
LAVINE, LS ;
CARRAS, R ;
ROSENTHAL, AD ;
SUMNER, P .
JOURNAL OF NEUROSURGERY, 1973, 39 (03) :362-369
[8]
ROENTGENOGRAPHIC EVALUATION OF LUMBAR SPINE FLEXION-EXTENSION IN ASYMPTOMATIC INDIVIDUALS [J].
HAYES, MA ;
HOWARD, TC ;
GRUEL, CR ;
KOPTA, JA .
SPINE, 1989, 14 (03) :327-331
[9]
Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement [J].
Inufusa, A ;
An, HS ;
Lim, TH ;
Hasegawa, T ;
Haughton, VM ;
Nowicki, BH .
SPINE, 1996, 21 (21) :2412-2420
[10]
LARGE COMPRESSIVE PRELOADS DECREASE LUMBAR MOTION SEGMENT FLEXIBILITY [J].
JANEVIC, J ;
ASHTONMILLER, JA ;
SCHULTZ, AB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :228-236