Effect of outflow orientation on heat transfer and pressure drop in a triangular duct with an array of tangential jets

被引:14
作者
Hwang, JJ [1 ]
Chang, BY [1 ]
机构
[1] Chung Hua Univ, Dept Engn Mech, Hsinchu 300, Taiwan
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2000年 / 122卷 / 04期
关键词
augmentation; heat transfer; impingement; jets; turbines;
D O I
10.1115/1.1318216
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments are conducted to study the heat transfer and pressure drop characteristics in a triangular duct cooled by an array of tangential jets, simulating the leading-edge cooling circuit of a turbine blade. Coolant ejected from a high-pressure plenum through an array of orifices is aimed at the leading-edge apex and exits from the radial outlets. Three different outflow orientations, namely coincident with the entry flow, opposed to the entry flow and both, are tested for various Reynolds numbers (12600 less than or equal to Re less than or equal to 42000). A transient liquid crystal technique is used to measure the detailed heat transfer coefficients on two walls forming the leading-edge apex. Flow rate across each jet hole and the crossflow development, which are closely related to the local heat transfer characteristics, are also measured. Results show that increasing Re increases the heat transfer on both walls. The outflow orientation affects significantly the local heat transfer characteristics through influencing the jet flow, together with the crossflow in the triangular duct. The triangular duct with two openings is recommended since it has the highest wall-averaged heat transfer and the moderate loss coefficient among the three outflow orientations investigated. Correlations for wall-averaged Nusselt number and loss coefficient in the triangular duct have been developed by considering the Reynolds number for three different outflow orientations.
引用
收藏
页码:669 / 678
页数:10
相关论文
共 23 条
[1]
BUNKER RS, 1990, J TURBOMACH, V112, P451, DOI 10.1115/1.2927680
[2]
CHENG CS, 1998, THESIS CHUNG HUA U T
[3]
Chupp R.E., 1969, J. Aircr., V6, P203
[4]
Dittus F.W., 1930, University of California Publications in Engineering, V2, P443, DOI DOI 10.1016/0735-1933(85)90003-X
[5]
HEAT-TRANSFER CHARACTERISTICS FOR JET ARRAY IMPINGEMENT WITH INITIAL CROSS-FLOW [J].
FLORSCHUETZ, LW ;
METZGER, DE ;
SU, CC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (01) :34-41
[6]
STREAMWISE FLOW AND HEAT-TRANSFER DISTRIBUTIONS FOR JET ARRAY IMPINGEMENT WITH CROSS-FLOW [J].
FLORSCHUETZ, LW ;
TRUMAN, CR ;
METZGER, DE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1981, 103 (02) :337-342
[7]
PERIODIC STREAMWISE VARIATIONS OF HEAT-TRANSFER COEFFICIENTS FOR IN-LINE AND STAGGERED ARRAYS OF CIRCULAR JETS WITH CROSS-FLOW OF SPENT AIR [J].
FLORSCHUETZ, LW ;
BERRY, RA ;
METZGER, DE .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1980, 102 (01) :132-137
[8]
HEDLUND CR, 1999, 99GT164 ASME
[9]
HEDLUND CR, 1999, ASME, V121, P803
[10]
Detailed heat transfer distributions under an array of orthogonal impinging jets [J].
Huang, YZ ;
Ekkad, SV ;
Han, JC .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1998, 12 (01) :73-79