Automated oscillometric determination of the ankle - Brachial index provides accuracy necessary for office practice

被引:89
作者
Beckman, JA [1 ]
Higgins, CO [1 ]
Gerhard-Herman, M [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Div Cardiovasc, Boston, MA 02115 USA
关键词
vascular diseases; atherosclerosis;
D O I
10.1161/01.HYP.0000196686.85286.9c
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Peripheral arterial disease (PAD) remains underdiagnosed by primary care and cardiovascular physicians. The office-based assessment of PAD is limited by the need for specialized equipment and the time required for performance of the ankle-brachial index (ABI). We explored whether the accuracy of automated ABI measurement by oscillometry compared favorably with the gold-standard method using continuous-wave Doppler ultrasound. Consecutive patients referred to our university hospital noninvasive vascular laboratory for ABI measurement were invited for participation. Of 205 patients, 201 participated, including 55 with PAD. The ABI was measured by automated oscillometry and Doppler ultrasound. The test of trends revealed a correlation coefficient of 0.78 in the left leg and 0.78 in the right leg (P<0.01 for both). The mean ABI difference between methods was 0.04 +/- 0.01 and 0.06 +/- 0.01, respectively, in the left and right legs. The differences between the methods followed a normal distribution. Oscillometric determination of the ABI provides an accurate determination of the ABI in an outpatient population. Our findings show automated oscillometry to be a reliable and easier method of ABI measurement, lowering the barrier to incorporation of this diagnostic test into clinical practice.
引用
收藏
页码:35 / 38
页数:4
相关论文
共 19 条
[1]  
*ADM US FDA, 1997, NON BLOOD PRESS NIBP
[2]   Quantitative and qualitative progression of peripheral arterial disease by non-invasive testing [J].
Bird, CE ;
Criqui, MH ;
Fronek, A ;
Denenberg, JO ;
Klauber, MR ;
Langer, RD .
VASCULAR MEDICINE, 1999, 4 (01) :15-21
[3]  
*CAS MED SYST, 2005, CAS MED SYST 1 740 M
[4]   High prevalence of peripheral arterial disease and co-morbidity in 6880 primary care patients: cross-sectional study [J].
Diehm, C ;
Schuster, A ;
Allenberg, JR ;
Darius, H ;
Haberl, R ;
Lange, S ;
Pittrow, D ;
von Stritzky, B ;
Tepohl, G ;
Trampisch, HJ .
ATHEROSCLEROSIS, 2004, 172 (01) :95-105
[5]   Variation in measurement of ankle-brachial pressure index in routine clinical practice [J].
Fisher, CM ;
Burnett, A ;
Makeham, V ;
Kidd, J ;
Glasson, M ;
Harris, JP .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (05) :871-875
[6]  
HEINRICH J, 1995, THROMB HAEMOSTASIS, V73, P374
[7]   EFFECT OF DIAGNOSTIC-CRITERIA ON THE PREVALENCE OF PERIPHERAL ARTERIAL-DISEASE - THE SAN-LUIS VALLEY DIABETES STUDY [J].
HIATT, WR ;
HOAG, S ;
HAMMAN, RF .
CIRCULATION, 1995, 91 (05) :1472-1479
[8]   The Minnesota Regional Peripheral Arterial Disease Screening Program: toward a definition of community standards of care [J].
Hirsch, AT ;
Halverson, SL ;
Treat-Jacobson, D ;
Hotvedt, PS ;
Lunzer, MM ;
Krook, S ;
Rajala, S ;
Hunninghake, DB .
VASCULAR MEDICINE, 2001, 6 (02) :87-96
[9]   Peripheral arterial disease detection, awareness, and treatment in primary care [J].
Hirsch, AT ;
Criqui, MH ;
Treat-Jacobson, D ;
Regensteiner, JG ;
Creager, MA ;
Olin, JW ;
Krook, SH ;
Hunninghake, DB ;
Comerota, AJ ;
Walsh, ME ;
McDermott, MM ;
Hiatt, WR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (11) :1317-1324
[10]   CLINICAL-EVALUATION OF SEMIAUTOMATIC AND AUTOMATIC DEVICES FOR HOME BLOOD-PRESSURE MEASUREMENT - COMPARISON BETWEEN CUFF-OSCILLOMETRIC AND MICROPHONE METHODS [J].
IMAI, Y ;
ABE, K ;
SASAKI, S ;
MINAMI, N ;
MUNAKATA, M ;
SAKUMA, H ;
HASHIMOTO, J ;
SEKINO, H ;
IMAI, K ;
YOSHINAGA, K .
JOURNAL OF HYPERTENSION, 1989, 7 (12) :983-990