Individual load impedance specification for a stable DC distributed power system

被引:78
作者
Feng, XG [1 ]
Ye, ZH [1 ]
Xing, K [1 ]
Lee, FC [1 ]
Borojevic, D [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Virginia Power Elect Ctr, Blacksburg, VA 24061 USA
来源
APEC'99: FOURTEENTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, CONFERENCE PROCEEDINGS, VOLS 1 & 2 | 1999年
关键词
D O I
10.1109/APEC.1999.750480
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper continues the effort to define load impedance specification for a stable DC distributed power system [1-4]. To improve the existing load impedance specification, an alternative forbidden region for Z(o)/Z(i) is proposed, based on which individual impedance specification for each load is defined. Theoretical verification, accompanied with simulation results, shows that the proposed impedance specification is a sufficient condition for small signal system stability. Finally, conservativeness in load impedance specification is discussed.
引用
收藏
页码:923 / 929
页数:3
相关论文
共 12 条
[1]  
Cho B. H., 1988, IEEE Transactions on Power Electronics, V3, P44, DOI 10.1109/63.4330
[2]  
GHOLDSTON EW, IECEC 96, P166
[3]  
Huliehel F. A., 1993, IECEC-93. Proceedings of the 28th Intersociety Energy Conversion Engineering Conference, P321
[4]  
Lewis L. R., 1989, P IEEE POW EL SPEC C, V1, P152
[5]  
Middlebrook R., 1976, P IEEE IND APPL SOC, P91
[6]  
NEEDHAM BR, 1993, IECEC 93 P 28 INT EN, V1, P309
[7]  
PATIL A, 1992, ASSESSMENT SPACE STA
[8]  
SCHULZ S, 1990, IEEE POWER ELECTRON, P611, DOI 10.1109/PESC.1990.131244
[9]  
SCHULZ SE, 1991, THESIS VPI SU BLACKS
[10]  
THANDI G, 1997, THESIS VPI SU BLACKS