Reproducibility of a knee and hip proprioception test in healthy older adults

被引:26
作者
Arvin, Mina [1 ]
Hoozemans, Marco J. M. [1 ,3 ,4 ]
Burger, Bart J. [3 ,4 ]
Verschueren, Sabine M. P. [2 ,5 ]
van Dieen, Jaap H. [1 ,6 ]
Pijnappels, Mirjam [1 ]
机构
[1] Vrije Univ Amsterdam, MOVE Res Inst Amsterdam, Fac Human Movement Sci, NL-1081 BT Amsterdam, Netherlands
[2] Fac Kinesiol & Rehabil Sci, Dept Rehabil Sci, Leuven, Belgium
[3] Ctr Orthopaed Res Alkmaar CORAL, Orthopaed Outpatient Dept, Med Ctr Alkmaar, Alkmaar, Netherlands
[4] Med Ctr Alkmaar, Ctr Orthopaed Res Alkmaar CORAL, Orthopaed Outpatient Dept, Alkmaar, Netherlands
[5] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Dept Rehabil Sci, Leuven, Belgium
[6] King Abdulaziz Univ, Jeddha, Saudi Arabia
关键词
Reliability; Agreement; Position sense; Lower limb; Standing; Elderly; JOINT POSITION SENSE; SENSORIMOTOR FUNCTION; LATERAL STABILITY; RELIABILITY; OSTEOARTHRITIS; INDIVIDUALS; BALANCE; PAIN; AGE; REHABILITATION;
D O I
10.1007/s40520-014-0255-6
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
030301 [社会学]; 100201 [内科学];
摘要
Background Proprioception can be assessed by measuring joint position sense (JPS). Most studies have focused on JPS of the knee joint while literature for other joints especially for hip JPS is scarce. Although some studies have evaluated proprioception of the knee joint, the reproducibility of methods has rarely been investigated. Aims To estimate intrasession reliability and agreement of an active-active JPS test for hip flexion/abduction and knee flexion in healthy older adults. Methods Nineteen healthy older adults participated in this study. The proprioception of the hip (flexion and abduction) and knee (flexion) were assessed in both legs using the "active-active" reproduction technique. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and limits of agreement (LOA) were estimated for relative angular error (RE), absolute angular error (AE), and variable angular error (VE). Results Reliability of our JPS test was substantial to almost perfect for the RE for both joints and legs (ICC values ranging from 0.75 to 0.93). We also found that the ICC values for AE were substantial for knee flexion and hip abduction of the left and right leg. The ICC results of VE showed poor reliability for hip and knee joints. SEM and LOA values for hip abduction were generally lower than for hip and knee flexion, indicating lower measurement error or more precise scores for the proprioception test of hip abduction. Conclusion(s) Proprioceptive acuity of the knee and hip joints in healthy older adults can be reliably assessed with an active-active procedure in a standing position with respect to relative and absolute error.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 41 条
[1]
Pointing in 3D space to remembered targets. I. Kinesthetic versus visual target presentation [J].
Adamovich, SV ;
Berkinblit, MB ;
Fookson, O ;
Poizner, H .
JOURNAL OF NEUROPHYSIOLOGY, 1998, 79 (06) :2833-2846
[2]
Andersen SB., 1995, J Sport Rehabil, V4, P165
[3]
Proprioceptive changes in the contralateral knee joint following anterior cruciate injury [J].
Arockiaraj, J. ;
Korula, R. J. ;
Oommen, A. T. ;
Devasahayam, S. ;
Wankhar, S. ;
Velkumar, S. ;
Poonnoose, P. M. .
BONE & JOINT JOURNAL, 2013, 95B (02) :188-191
[4]
Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[5]
Abnormal knee joint position sense in individuals with patellofemoral pain syndrome [J].
Baker, V ;
Bennell, K ;
Stillman, B ;
Cowan, S ;
Crossley, K .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (02) :208-214
[6]
EFFECT OF ARTICULAR DISEASE AND TOTAL KNEE ARTHROPLASTY ON KNEE-JOINT POSITION SENSE [J].
BARRACK, RL ;
SKINNER, HB ;
COOK, SD ;
HADDAD, RJ .
JOURNAL OF NEUROPHYSIOLOGY, 1983, 50 (03) :684-687
[7]
Reliability and Precision of Hip Proprioception Methods in Healthy Individuals [J].
Benjaminse, Anne ;
Sell, Timothy C. ;
Abt, John P. ;
House, Anthony J. ;
Lephart, Scott M. .
CLINICAL JOURNAL OF SPORT MEDICINE, 2009, 19 (06) :457-463
[8]
Effects of experimentally-induced anterior knee pain on knee joint position sense in healthy individuals [J].
Bennell, K ;
Wee, E ;
Crossley, K ;
Stillman, B ;
Hodges, P .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (01) :46-53
[9]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[10]
Validation of a method to measure the proprioception of the knee [J].
Boerboom, A. L. ;
Huizinga, M. R. ;
Kaan, W. A. ;
Stewart, R. E. ;
Hof, A. L. ;
Bulstra, S. K. ;
Diercks, R. L. .
GAIT & POSTURE, 2008, 28 (04) :610-614