Monte Carlo treatment planning for stereotactic radiosurgery

被引:49
作者
Solberg, TD [1 ]
DeMarco, JJ [1 ]
Holly, FE [1 ]
Smathers, JB [1 ]
DeSalles, AAF [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Jonsson Comprehens Canc Ctr, Div Neurosurg,Dept Radiat Oncol, Los Angeles, CA 90095 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Monte Carlo; treatment planning; stereotactic radiosurgery;
D O I
10.1016/S0167-8140(98)00065-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: In radiosurgery treatment planning there is general acceptance that the target volume can be assumed to be homogeneous and that corrections for variations in contour are unnecessary. Thus, dose algorithms employed in radiosurgery treatment planning are quite unsophisticated; in almost every case the algorithms are the simple product of tissue-maximum and off-axis ratios and an output factor. In small photon beams, however, the lack of side scatter equilibrium compromises these assumptions. Methods: In this work we have employed Monte Carlo techniques in an attempt to obtain a more accurate representation of radiosurgical dose distributions. Specifically, the Monte Carlo system which we have devised traces the paths of primary and secondary radiation through a patient-specific anatomical representation defined by computed tomography data. In this manner the perturbation effects from external contour changes and internal tissue heterogeneities are accounted for completely. The ability to precisely mimic multi-beam multi-are stereotactic delivery has been incorporated into our Monte Carlo treatment planning interface. Results: Subsequent calculations show that substantial differences can exist when homogeneity is not assumed. Tissue heterogeneities produce a lateral broadening of the beam, resulting in a smaller volume contained within the higher isodose levels (80-90%) with a corresponding increase in the volume treated at the lower isodose levels (<50%). Conclusions: These results suggest that further investigation and refinement of radiosurgery dose algorithms is in order. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:73 / 84
页数:12
相关论文
共 38 条
[1]  
[Anonymous], 1988, MONTE CARLO TRANSPOR
[2]  
ARELLANO AR, 1996, MED PHYS, V23, P1492
[3]  
BARCIASALORIO JL, 1994, ACT NEUR S, V62, P111
[4]  
Berger M, 1963, METHODS COMPUTATIONA, VI
[5]  
BERGER MJ, 1968, CCC107 RAD SHIELD IN
[6]  
BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475
[7]   ATTENUATION IN VERY NARROW PHOTON BEAMS [J].
BJARNGARD, BE ;
TSAI, JS ;
RICE, RK .
RADIATION RESEARCH, 1989, 118 (02) :195-200
[8]  
BRIESMEISTER JF, 1993, LA12625
[9]  
CHUI CS, 1988, MED PHYS S1, V33, P21
[10]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11