共 4 条
Pathophysiology of proximal perigraft endoleak following endovascular repair of abdominal aortic aneurysms: a study using a flow model
被引:32
作者:
Albertini, JN
[1
]
Macierewicz, JA
[1
]
Yusuf, SW
[1
]
Wenham, PW
[1
]
Hopkinson, BR
[1
]
机构:
[1] Queens Med Ctr, Dept Vasc Surg, Nottingham, England
关键词:
absominal aortic aneurysm;
endovascular repair;
endoleak;
flow model;
pathophysiology;
stent-graft;
D O I:
10.1053/ejvs.2001.1385
中图分类号:
R61 [外科手术学];
学科分类号:
摘要:
Objective: to design a flow model to determine whether and why increased proximal neck angulation correlates with increased risk of proximal perigraft endoleak (PPE) flow. Methods: a tapered stent-graft (Gianturco stent + Dacron) was deployed with proximal and distal necks made of silicone. The amount of PPE was measured over 30-s periods while the angulation of the proximal neck was increased. Results: PPE flow increased significantly for angulations greater than or equal to 30 degrees. The graft was lifted off the neck wall and gaps between the stent-graft and the neck created. Conclusion: greater neck angulation increased PPE flow. The stent-graft was lifted off the neck and subsequent gaps created. This model could be used to compare available stent-grafts and to test new designs that would improve the seal in angulated necks.