Exergy modeling of a new solar driven trigeneration system

被引:207
作者
Al-Sulaiman, Fahad A. [1 ,3 ]
Dincer, Ibrahim [2 ]
Hamdullahpur, Feridun [3 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
[2] Univ Ontario, Inst Technol Oshawa, Fac Engn & Appl Sci, Toronto, ON, Canada
[3] Univ Waterloo, Mech & Mechatron Engn Dept, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Trigeneration; Parabolic trough solar collectors; Organic Rankine cycle; Thermal storage tank; Exergy efficiency; Exergy destruction rate; ORGANIC RANKINE-CYCLE; OPTIMIZATION; STORAGE; ENERGY;
D O I
10.1016/j.solener.2011.06.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, exergy modeling is used to assess the exergetic performance of a novel trigeneration system using parabolic trough solar collectors (PTSC)and an organic Rankine cycle (ORC). Four cases are considered: electrical-power, cooling-cogeneration, heating-cogeneration, and trigeneration. In this trigeneration system a single-effect absorption chiller is utilized to provide the necessary cooling energy and a heat exchanger is utilized to provide the necessary heating energy. The trigeneration system considered is examined using three modes of operation. They are: solar mode during the low-solar radiation time of the day, solar and storage mode during the high-solar radiation time of the day, and storage mode during night time. The storage mode is operated through the heat collected in a thermal storage tank during the solar and storage mode. The exergy efficiencies and exergy destruction rates are examined under the variation of the ORC evaporator pinch point temperature, ORC pump inlet temperature, and turbine inlet pressure. This study reveals that the maximum electrical-exergy efficiency for the solar mode is 7%, for the solar and storage mode is 3.5%, and for the storage mode is 3%. Alternatively, when trigeneration is used, the exergy efficiency increases noticeably. The maximum trigeneration-exergy efficiency for the solar mode is 20%, for solar and storage mode is 8%, and for the storage mode is 7%. Moreover, this study shows that the main sources of exergy destruction rate are the solar collectors and ORC evaporators. Therefore, careful selection and design of these two components are essential to reduce the exergy destructed by them and, thus, increase the exergy efficiencies of the system. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2228 / 2243
页数:16
相关论文
共 38 条
[1]   Trigeneration: A comprehensive review based on prime movers [J].
Al-Sulaiman, Fahad A. ;
Hamdullahpur, Feridun ;
Dincer, Ibrahim .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2011, 35 (03) :233-258
[2]  
ALSULAIMAN FA, 2011, PERFORMANCE AS UNPUB
[3]  
*AM SOC HEAT REFR, 2005, ASHRAE HDB FUND, pCH1
[4]  
[Anonymous], 2007, 3LSEVIER SCI
[5]  
[Anonymous], 1999, P 1999 ASME INT SOL
[6]  
[Anonymous], 1994, SANDIA941884 SAND NA
[7]   Modelling and optimisation of solar organic rankine cycle engines for reverse osmosis desalination [J].
Carles Bruno, Joan ;
Lopez-Villada, Jesus ;
Letelier, Eduardo ;
Romera, Silvia ;
Coronas, Alberto .
APPLIED THERMAL ENGINEERING, 2008, 28 (17-18) :2212-2226
[8]   Comparison of solar technologies for driving a desalination system by means of an organic Rankine cycle [J].
Delgado-Torres, Agustin Manuel ;
Garcia-Rodriguez, Lourdes .
DESALINATION, 2007, 216 (1-3) :276-291
[9]  
Duffle JA., 2006, Solar engineering of thermal processes, V3rd
[10]   Parabolic-trough solar collectors and their applications [J].
Fernandez-Garcia, A. ;
Zarza, E. ;
Valenzuela, L. ;
Perez, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (07) :1695-1721