Postoperative drainage of knee arthroplasty is not necessary - A randomized study of 90 patients

被引:101
作者
Adalberth, G [1 ]
Bystrom, S [1 ]
Kolstad, K [1 ]
Mallmin, H [1 ]
Milbrink, J [1 ]
机构
[1] Univ Uppsala Hosp, Dept Orthoped, SE-75185 Uppsala, Sweden
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1998年 / 69卷 / 05期
关键词
D O I
10.3109/17453679808997781
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the management of postoperative drainage after total knee replacement (TKR). 90 primary total knee joint arthroplasties were prospectively randomized into 3 groups: a) no drain, b) an autotransfusion system, c) a standard disposable closed suction drainage system. We monitored hemoglobin and hematocrit values, drainage volume and transfusions (homologous and autologous), range of knee motion, knee swelling and hospital slay. Parameters were recorded preoperatively, days 0-8 and 4 months postoperatively. No significant differences were seen between the groups in any of the parameters measured. The results show no benefit from using postoperative drainage systems in knee arthroplasties. Savings of SEK 400 (USD 55) per patient would have resulted if drains had not been used at all.
引用
收藏
页码:475 / 478
页数:4
相关论文
共 14 条
  • [1] THE EFFICACY OF SUCTION DRAINS AFTER ROUTINE TOTAL JOINT ARTHROPLASTY
    BEER, KJ
    LOMBARDI, AV
    MALLORY, TH
    VAUGHN, BK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (04) : 584 - 587
  • [2] BURKART BC, 1994, CLIN ORTHOP RELAT R, P147
  • [3] WHY USE DRAINS
    COBB, JP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (06): : 993 - 995
  • [4] DALEN T, 1996, AM J KNEE SURG, V9, P177
  • [5] Gannon D M, 1991, J Arthroplasty, V6, P109, DOI 10.1016/S0883-5403(11)80004-5
  • [6] POSTOPERATIVE BLOOD SALVAGE IN TOTAL KNEE ARTHROPLASTY USING THE SOLCOTRANS AUTOTRANSFUSION SYSTEM
    MARKS, RM
    VACCARO, AR
    BALDERSTON, RA
    HOZACK, WJ
    BOOTH, RE
    ROTHMAN, RH
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (04) : 433 - 437
  • [7] Martin J W, 1992, J Arthroplasty, V7, P205, DOI 10.1016/0883-5403(92)90019-M
  • [8] REILLY TJ, 1986, CLIN ORTHOP RELAT R, P238
  • [9] CLOSED WOUND DRAINAGE IN TOTAL HIP OR TOTAL KNEE REPLACEMENT - A PROSPECTIVE RANDOMIZED STUDY
    RITTER, MA
    KEATING, EM
    FARIS, PM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (01) : 35 - 38
  • [10] POSTOPERATIVE BLOOD SALVAGE USING THE CELL SAVER AFTER TOTAL JOINT ARTHROPLASTY
    SEMKIW, LB
    SCHURMAN, DJ
    GOODMAN, SB
    WOOLSON, ST
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06) : 823 - 827