High-resolution QRS fiducial point corrections in sparsely sampled ECG recordings

被引:9
作者
Bragge, T [1 ]
Tarvainen, MP [1 ]
Ranta-Aho, PO [1 ]
Karjalainen, PA [1 ]
机构
[1] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
关键词
electrocardiogram; ECG; QRS fiducial point; shape estimation; modeling; interpolation;
D O I
10.1088/0967-3334/26/5/013
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A model based high-resolution QRS fiducial point correction algorithm, which is suitable for sparsely sampled electrocardiogram (ECG) recordings, is presented. The presented method can be divided into three steps. First, the initial QRS fiducial points are estimated by using ordinary interpolation methods. Then, the data points of each QRS are extracted and centered in time and the shape of the QRS complex is estimated by nonlinearly fitting a double exponential function to the extracted data points. Finally, the estimated model and its derivative are linearly fitted to the data points of each QRS complex separately and new fiducial point estimates are obtained. The proposed method is tested with simulations and real ECG data. As a result, it is observed that the proposed method is also suitable for asymmetric QRS complexes unlike, e.g., the commonly used cubic spline interpolation method.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 8 条
[1]
Camm AJ, 1996, CIRCULATION, V93, P1043
[2]
Real time electrocardiogram QRS detection using combined adaptive threshold [J].
Christov, Ivaylo I. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[3]
Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation [J].
Daskalov, I ;
Christov, I .
MEDICAL ENGINEERING & PHYSICS, 1997, 19 (04) :375-379
[4]
Ventricular beat detection in single channel electrocardiograms [J].
Dotsinsky, Ivan A. ;
Stoyanov, Todor V. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[5]
Bias and uncertainty in heart rate variability spectral indices due to the finite ECG sampling frequency [J].
García-González, MA ;
Fernández-Chimeno, M ;
Ramos-Castro, J .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (02) :489-504
[6]
SAMPLING FREQUENCY OF THE ELECTROCARDIOGRAM FOR SPECTRAL-ANALYSIS OF THE HEART-RATE-VARIABILITY [J].
MERRI, M ;
FARDEN, DC ;
MOTTLEY, JG ;
TITLEBAUM, EL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :99-106
[7]
A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236
[8]
THE ACCURACY OF POWER-SPECTRUM ANALYSIS OF HEART-RATE-VARIABILITY FROM ANNOTATED RR LISTS GENERATED BY HOLTER SYSTEMS [J].
PINNA, GD ;
MAESTRI, R ;
DICESARE, A ;
COLOMBO, R ;
MINUCO, G .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 (02) :163-179