Platinization of shapable electroconductive polymer film for an improved glucose sensor

被引:29
作者
Khan, GF [1 ]
Wernet, W [1 ]
机构
[1] CIBA JAPAN, INT RES LABS, NEW MAT RES DEPT, TAKARAZUKA, HYOGO 665, JAPAN
关键词
D O I
10.1149/1.1837208
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper describes a novel electrode material for the preparation of a first generation amperometric biosensor. The material consists of a flexible conductive polymer film of polypyrrole doped with polyanions and a layer of microporous Pt black, prepared electrochemically on the polymer film. Sensors fabricated with this material produce a comparatively higher H2O2 oxidation current at a lower applied potential. Glucose sensors were prepared by adsorbing glucose oxi dase at the porous Pt black structure, covering with gelatin, and finally cross-linking with glutaraldehyde at dry condition. The developed sensors showed significantly improved performance over similar reported sensor systems. The performance of the glucose sensor was evaluated by a specially designed flow injection analysis (FIA) system. The sensors were continuously polarized at 25 degrees C and glucose samples were automatically injected at 30 min intervals. The sensors worked at 0.3 to 0.4 V and produced a huge current response (>1 mA/cm(2)) with a wide linear range of detection (0 to 100 mM). The system effectively recycles oxygen, thus, the response current was not affected by a variation of oxygen concentration of the buffer. The interference of ascorbic acid, uric acid, bilirubin, etc. (at a physiological level) produced a current within the experimental error level. The sensor showed an extended working and shelf life.
引用
收藏
页码:3336 / 3342
页数:7
相关论文
共 25 条
[1]   PROPERTIES OF POROUS ACTIVATED CARBON ELECTRODE MATERIALS USED AS SENSORS FOR GLUCOSE [J].
ARMSTRONG, RD ;
NEWTON, HV .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 364 (1-2) :87-94
[2]   EFFECT OF PRE-TREATMENT OF PLATINUM FOR MODIFIED PLATINUM WIRE GLUCOSE-OXIDASE AMPEROMETRIC ELECTRODES [J].
BEH, SK ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (01) :29-32
[3]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[4]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN A POLY [VINYL ALCOHOL] MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY GAMMA-IRRADIATION [J].
GALIATSATOS, C ;
IKARIYAMA, Y ;
MARK, JE ;
HEINEMAN, WR .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (01) :47-61
[5]   POTENTIAL GLUCOSE SENSOR FOR PERIOPERATIVE BLOOD-GLUCOSE CONTROL IN DIABETES-MELLITUS [J].
GREENOUGH, KR ;
SKILLEN, AW ;
MCNEIL, CJ .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (01) :23-28
[6]   GLUCOSE ENZYME ELECTRODE PREPARATION BY THE CODEPOSITION OF PLATINUM AND GLUCOSE-OXIDASE ONTO GLASSY-CARBON [J].
GUNASINGHAM, H ;
TAN, CB .
ELECTROANALYSIS, 1989, 1 (03) :223-227
[7]  
Hagiwara Yukihiko, 1993, Neurosciences, V19, P37
[8]   IMMOBILIZATION OF LACTATE OXIDASE IN A POLY(VINYL ALCOHOL) MATRIX ON PLATINIZED GRAPHITE-ELECTRODES BY CHEMICAL CROSS-LINKING WITH ISOCYANATE [J].
HAJIZADEH, K ;
HALSALL, HB ;
HEINEMAN, WR .
TALANTA, 1991, 38 (01) :37-47
[9]   ELECTROCHEMICAL PLATINIZATION OF RETICULATED VITREOUS CARBON ELECTRODES TO INCREASE BIOSENSOR RESPONSE [J].
HEIDER, GH ;
SASSO, SV ;
HUANG, KM ;
YACYNYCH, AM ;
WIECK, HJ .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1106-1110
[10]   SURFACE CONTROL OF PLATINIZED PLATINUM AS A TRANSDUCER MATRIX FOR MICRO-ENZYME ELECTRODES [J].
IKARIYAMA, Y ;
YAMAUCHI, S ;
YUKIASHI, T ;
USHIODA, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 251 (02) :267-274