Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads

被引:182
作者
Chen, G. [1 ]
Sequeira, F. [1 ]
Tyan, D. B. [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Pathol, Histocompatibil Immunogenet & Dis Profiling Lab, Palo Alto, CA 94304 USA
关键词
HLA antibodies; Transplantation; Antibody-mediated rejection; Complement; Donor-specific antibodies; HLA ANTIBODIES; KIDNEY-TRANSPLANTATION; MEDIATED REJECTION; RENAL-ALLOGRAFTS; GRAFT FAILURE; ALLOANTIBODIES; ACCOMMODATION; REACTIVITY;
D O I
10.1016/j.humimm.2011.07.001
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
It has been known for 40 years that cytotoxic human leukocyte antigen (HLA) antibodies are associated with graft rejection. However, the complement-dependent cytotoxicity assay (CDC) used to define these clinically deleterious antibodies suffers from a lack of sensitivity and specificity. Recently, methods exploiting immunoglobulin G (IgG) antibody binding to HLA single antigen beads (SAB) have overcome sensitivity and specificity drawbacks but introduced a new dilemma: which of the much broader set of antibodies defined by these methods are clinically relevant. To address this, we developed a complement-fixing C1q assay on the HLASAB that combines sensitivity, specificity, and functional potential into one assay. We compared the CDC, IgG, and C1q assays on 96 sera having 2.118 defined antibodies and determined that CDC detects only 19% of complement-fixing antibodies detected by C1q, whereas C1q detects only 47% of antibodies detected by IgG. In the same patient, there is no predictability by IgG mean fluorescence intensity (MFI) as to which of the antibodies will bind C1q because fixation is independent of MFI values. In 3 clinical studies, C1q(+) antibodies appear to be more highly correlated than those detected by IgG alone for antibody-mediated rejection in hearts as well as for kidney transplant glomerulopathy and graft failure. (C) 2011 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:849 / 858
页数:10
相关论文
共 31 条
[1]  
ALEXANDRE GPJ, 1987, TRANSPLANT P, V19, P4538
[2]   C4d deposits in renal allografts are associated with inferior graft outcome [J].
Böhmig, GA ;
Exner, M ;
Watschinger, B ;
Wenter, C ;
Wahrmann, M ;
Österreicher, C ;
Säemann, MD ;
Mersich, N ;
Hörl, WH ;
Zlabinger, GJ ;
Regele, H .
TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) :1151-1152
[3]   Strategies for human leukocyte antigen antibody detection [J].
Bray, Robert A. ;
Gebel, Howard M. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2009, 14 (04) :392-397
[4]   Post-transplantation antibody monitoring and HLA antibody epitope identification [J].
Cai, Junchao ;
Terasaki, Paul I. .
CURRENT OPINION IN IMMUNOLOGY, 2008, 20 (05) :602-606
[5]   Clinical usefulness of a novel C1q assay to detect immunoglobulin G antibodies capable of fixing complement in sensitized pediatric heart transplant patients [J].
Chin, Clifford ;
Chen, Ge ;
Sequeria, Flavia ;
Berry, Gerald ;
Siehr, Stephanie ;
Bernstein, Daniel ;
Rosenthal, David ;
Reinhartz, Olaf ;
Tyan, Dolly .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (02) :158-163
[6]   TWO CASES OF DONOR SPECIFIC ANTIBODIES (DSA): ONE PATIENT'S DSA HAD IgG SUBCLASS 1 & 3 WITH GRAFT FAILURE, AND THE OTHER PATIENT HAD DSA IgG SUBCLASS 4 AND THE GRAFT IS FUNCTIONING WELL. [J].
Cicciarelli, James ;
Adamson, Robert ;
Steinberg, Steven ;
Browne, Barry ;
Pitpitan, Benny ;
Williams, Bruce ;
Kasahara, Nori .
HUMAN IMMUNOLOGY, 2010, 71 :S5-S5
[7]   IgG SUBCLASS ANTIBODIES IN TRANSPLANT RECIPIENT SERA: AN IgG SUBCLASS SPECIFIC ASSAY TO DETERMINE THE "GOOD AND BAD" IgG IMMUNOGLOBULINS [J].
Cicciarelli, James ;
Kasahara, Noriyuki ;
Pitpitan, Bennie ;
Helstab-Houston, Kathryn ;
Hutchinson, Ian ;
Shah, Tariq .
HUMAN IMMUNOLOGY, 2009, 70 :S103-S103
[8]   Dimensions of Antibody-Mediated Rejection [J].
Colvin, R. B. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2010, 10 (07) :1509-1510
[9]   Antibody-mediated organ-allograft rejection [J].
Colvin, RB ;
Smith, RN .
NATURE REVIEWS IMMUNOLOGY, 2005, 5 (10) :807-817
[10]   Interpretation of Positive Flow Cytometric Crossmatch in the Era of the Single-Antigen Bead Assay [J].
Couzi, Lionel ;
Araujo, Caroline ;
Guidicelli, Gwendaline ;
Bachelet, Thomas ;
Moreau, Karine ;
Morel, Delphine ;
Robert, Gregoire ;
Wallerand, Herve ;
Moreau, Jean-Francois ;
Taupin, Jean-Luc ;
Merville, Pierre .
TRANSPLANTATION, 2011, 91 (05) :527-535