Optimizing current control performance in double winding asynchronous motors in large power inverter drives

被引:35
作者
De Camillis, L [1 ]
Matuonto, M
Monti, A
Vignati, A
机构
[1] Politecn Milan, Dipartimento Elettrotecn, I-20133 Milan, Italy
[2] Prod Dev Dept, Pittsburgh, PA 15239 USA
[3] Univ S Carolina, Dept Elect Engn, Columbia, SC 29208 USA
关键词
induction motors; variable speed drives; vector control;
D O I
10.1109/63.949500
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operation of ac drives in applications requiring high overload capability imposes hard working conditions on the electronic switching devices. The use of induction motors with two stator windings, fed by two inverter modules, allows large power rating in variable speed drives for high performance applications. This paper shows the structure and the main features of a field-oriented control for a double winding motor, fed by two GTO inverters. The operational results of a 850 kW drive, working as a melt pump in a polyethylene plant, are reported in order to describe the obtained performances.
引用
收藏
页码:676 / 685
页数:10
相关论文
共 14 条
[1]  
[Anonymous], 1992, ELECT MACHINES DRIVE
[2]  
BOATTINI F, 1998, P IEEE IECON 98 AACH
[3]  
Carpita M., 1996, EPE Journal, V5, P49
[4]  
FRASCOTTI M, P EPE 97 TRODH NORW
[5]  
Leonhard W., 1985, CONTROL ELECT DRIVES
[6]  
Lipo T., 1980, P INT C EL MACH ICEM, P860
[7]  
Marchesoni M., 1992, IEEE Transactions on Power Electronics, V7, P189, DOI 10.1109/63.124591
[8]  
MATUONTO M, P PEMC 98
[9]  
MONTI A, 1995, P EPE 95, P419
[10]  
MORISI L, 1995, P EPE 95 SEV SPAIN S