Narrowing and broadening parameters of H2O lines perturbed by He, Ne, Ar, Kr and nitrogen in the spectral range 1850-2240 cm-1

被引:72
作者
Claveau, C
Henry, A
Hurtmans, D
Valentin, A
机构
[1] Univ Paris 06, Lab Phys Mol & Applicat, CNRS, UPR 136, F-75252 Paris 05, France
[2] Free Univ Brussels, Lab Chim Phys Mol CP160 09, B-1050 Brussels, Belgium
关键词
D O I
10.1016/S0022-4073(00)00025-X
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Collision effects on water vapor at low concentration in mixture with noble gases and nitrogen have been studied by Fourier transform spectroscopy in a pressure range where line narrowing by dynamic confinement (Dicke effect) and collision broadening are observable, i.e. when the Voigt function cannot reproduce the observed profiles. Precise values of the broadening parameter have been obtained for R branch lines of the nu (2) band of H2O and narrowing parameter values were derived using the soft and hard collision models. Furthermore, it is shown that, when neglecting the confinement effect, systematic errors on the broadening parameters may be introduced and reach several percents for the narrowest lines corresponding to the highest J values. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:273 / 298
页数:26
相关论文
共 43 条
[1]  
[Anonymous], 1992, Spectroscopy of the Earth's atmosphere and interstellar medium
[2]   Anomalies of pressure broadening in the H-2 S-0(3) transition versus perturber concentration [J].
Anselm, N ;
Schieder, R ;
Winnewisser, G ;
Bonamy, J ;
Robert, D .
PHYSICAL REVIEW A, 1996, 53 (05) :3087-3091
[3]   CALCULATION OF LINE WIDTHS IN H2O-H2O AND H2O-O2 COLLISIONS [J].
BENEDICT, WS ;
KAPLAN, LD .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1964, 4 (03) :453-469
[4]   CALCULATION OF LINE WIDTHS IN H2O-N2 COLLISIONS [J].
BENEDICT, WS ;
KAPLAN, LD .
JOURNAL OF CHEMICAL PHYSICS, 1959, 30 (02) :388-399
[5]   IMPACT BROADENING OF MICROWAVE SPECTRA [J].
BENREUVEN, A .
PHYSICAL REVIEW, 1966, 145 (01) :7-+
[6]  
BERMAN PR, 1972, J QUANT SPECTROSC RA, V12, P1331, DOI 10.1016/0022-4073(72)90189-6
[7]  
CARDINET P, 1977, ACAD SC PARIS B, V284, P37
[8]   HIGH-PRECISION FREQUENCY CALIBRATION OF TUNABLE DIODE-LASERS STABILIZED ON AN INTERNALLY COUPLED FABRY-PEROT-INTERFEROMETER [J].
CLAR, HJ ;
SCHIEDER, R ;
REICH, M ;
WINNEWISSER, G .
APPLIED OPTICS, 1989, 28 (09) :1648-1656
[10]   MANY-BODY TREATMENT OF PRESSURE SHIFTS ASSOCIATED WITH COLLISIONAL BROADENING [J].
DAVIES, RW .