Correcting for deformation in skin-based marker systems

被引:181
作者
Alexander, EJ
Andriacchi, TP
机构
[1] Stanford Univ, Div Biomech Engn, Dept Mech Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Funct Restorat, Stanford, CA 94305 USA
关键词
in vivo skeletal movement; bone pose estimation; skin movement artifact;
D O I
10.1016/S0021-9290(00)00192-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A new technique is described that reduces error due to skin movement artifact in the opto-electronic measurement of in vivo skeletal motion. This work builds on a previously described point cluster technique marker set and estimation algorithm by extending the transformation equations to the general deformation case using a set of activity-dependent deformation models. Skin deformation during activities of daily living are modeled as consisting of a functional form defined over the observation interval (the deformation model) plus additive noise (modeling error). The method is described as an interval deformation technique. The method was tested using simulation trials with systematic and random components of deformation error introduced into marker position vectors. The technique was found to substantially outperform methods that require rigid-body assumptions. The method was tested in vivo on a patient fitted with an external fixation device (Ilizarov). Simultaneous measurements from markers placed on the Ilizarov device (fixed to bone) were compared to measurements derived from skin-based markers. The interval deformation technique reduced the errors in limb segment pose estimate by 33% and 25% compared to the classic rigid-body technique for position and orientation, respectively. This newly developed method has demonstrated that by accounting for the changing shape of the limb segment, a substantial improvement in the estimates of in vivo skeletal movement can be achieved. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 14 条
[1]
Andriacchi T.P., 1994, P CAN SOC BIOM, P221
[2]
A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics [J].
Andriacchi, TP ;
Alexander, EJ ;
Toney, MK ;
Dyrby, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (06) :743-749
[3]
CAPOZZO A, 1996, CLIN BIOMECH, V11, P90
[4]
Multiple anatomical landmark calibration for optimal bone pose estimation [J].
Cappello, A ;
Cappozzo, A ;
LaPalombara, PF ;
Lucchetti, L ;
Leardini, A .
HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) :259-274
[5]
Surface-marker cluster design criteria for 3-D bone movement reconstruction [J].
Cappozzo, A ;
Cappello, A ;
DellaCroce, U ;
Pensalfini, F .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1165-1174
[6]
Surface movement errors in shank kinematics and knee kinetics during gait [J].
Holden, JP ;
Orsini, JA ;
Siegel, KL ;
Kepple, TM ;
Gerber, LH ;
Stanhope, SJ .
GAIT & POSTURE, 1997, 5 (03) :217-227
[7]
MEASUREMENT OF LOWER-EXTREMITY KINEMATICS DURING LEVEL WALKING [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :383-392
[8]
3-DIMENSIONAL KINEMATICS OF THE HUMAN KNEE DURING WALKING [J].
LAFORTUNE, MA ;
CAVANAGH, PR ;
SOMMER, HJ ;
KALENAK, A .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :347-357
[9]
Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints [J].
Lu, TW ;
O'Connor, JJ .
JOURNAL OF BIOMECHANICS, 1999, 32 (02) :129-134
[10]
Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics [J].
Lucchetti, L ;
Cappozzo, A ;
Cappello, A ;
Della Croce, U .
JOURNAL OF BIOMECHANICS, 1998, 31 (11) :977-984