Chemically modified silica gel with p-dimethylaminobenzaldehyde for selective solid-phase extraction and preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) by ICP-OES

被引:128
作者
Cui, Yuemei [1 ]
Chang, Xijun [1 ]
Zhu, Xiangbing [1 ]
Luo, Haixia [1 ]
Hu, Zheng [1 ]
Zou, Xiaojun [1 ]
He, Qun [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
关键词
silica gel; p-dimethylaminobenzaldehyde (p-DMABD); Cr(III); Cu(II); Ni(II); Pb(II) and Zn(II); solid-phase extraction (SPE); ICP-OES; METAL-IONS; TRACE-METALS; ADSORPTION; SEPARATION; SORPTION; SORBENTS; COBALT; COPPER; SILVER; RESIN;
D O I
10.1016/j.microc.2007.04.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was >= 3, for Cu(II), Pb(II) and Zn(II) extraction it was >= 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L-1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g(-1), with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 mu g L-1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n=8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 40 条
[1]   Ethyleneimine anchored on thiol-modified silica gel surface - Adsorption of divalent cations and calorimetric data [J].
Arakaki, LNH ;
Nunes, LM ;
Simoni, JA ;
Airoldi, C .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 228 (01) :46-51
[2]  
BELLAMY LJ, 1964, INFRARED SPECTRA COM, P165
[3]   ANALYTICAL FRACTIONATION OF LABILE METALS IN SELECTED GROUNDWATER HUMIC SUBSTANCES BY MEANS OF CHELATING ION-EXCHANGER [J].
BURBA, P ;
WILLMER, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :167-171
[4]  
Dean J., 1998, EXTRACTION METHODS E
[5]  
Delacour ML, 1999, J APPL POLYM SCI, V73, P899, DOI 10.1002/(SICI)1097-4628(19990808)73:6<899::AID-APP6>3.0.CO
[6]  
2-O
[7]   PREPARATION AND ANALYTICAL PROPERTIES OF A CHELATING RESIN CONTAINING BICINE GROUPS [J].
DEV, K ;
RAO, GN .
TALANTA, 1995, 42 (04) :591-596
[8]   Determination of vanadium, manganese, silver and lead by graphite furnace atomic absorption spectrometry after preconcentration on silica-gel modified with 3-aminopropyltriethoxysilane [J].
Ekinci, C ;
Köklü, Ü .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (09) :1491-1495
[9]   Separation and preconcentration of cobalt after sorption onto amberlite XAD-2 loaded with 2-(2-thiazolylazo)-p-cresol [J].
Ferreira, SLC ;
de Brito, CF .
ANALYTICAL SCIENCES, 1999, 15 (02) :189-191
[10]  
FORSTNER U., 1983, METAL POLLUTION AQUA, V2