Effect of Organ Enhancement and Habitus on Estimation of Unenhanced Attenuation at Contrast-Enhanced Dual-Energy MDCT: Concepts for Individualized and Organ-Specific Spectral Iodine Subtraction Strategies

被引:23
作者
Miller, Chad M. [1 ]
Gupta, Rajan T. [1 ]
Paulson, Erik K. [1 ]
Neville, Amy M. [1 ]
Bashir, Mustafa R. [1 ]
Merkle, Elmar M. [1 ]
Boll, Daniel T. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
abdominal imaging; dual-energy MDCT; iodine extraction; MACROVESICULAR HEPATIC STEATOSIS; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; MULTIDETECTOR CT; IRON OVERLOAD; IMAGE QUALITY; LIVER-DONORS; RENAL MASSES; PHANTOM; WEIGHT; SYSTEM;
D O I
10.2214/AJR.10.4858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The purpose of this study was to assess whether habitus and organ enhancement influence iodine subtraction and should be incorporated into spectral subtraction algorithms. SUBJECTS AND METHODS. This study included 171 patients. In the unenhanced phase, MDCT was performed with single-energy acquisition (120 kVp, 250 mAs) and in the parenchymal phase with dual-energy acquisitions (80 kVp, 499 mAs; 140 kVp, 126 mAs). Habitus was determined by measuring trunk diameters and calculating circumference. Iodine subtraction was performed with input parameters individualized to muscle, fat, and blood ratio. Attenuation of the liver, pancreas, spleen, kidneys, and aorta was assessed in truly and virtually unenhanced image series. Pearson analysis was performed to correlate habitus with the input parameters. Analysis of truly unenhanced and virtually unenhanced images was performed with the Student t test; magnitude of variation was evaluated with Bland-Altman plots. Correction strategies were derived from organ-specific regression analysis of scatter-plots of truly unenhanced and virtually unenhanced attenuation and implemented in a pixel-by-pixel approach. Analysis of individual organ correction and truly unenhanced attenuation was performed with the Student t test. RESULTS. The correlations between habitus and blood ratio (r = 0.694) and attenuation variation of fat at 80 kVp (r = -0.468) and 140 kV (r = -0.454) were confirmed. Although overall mean attenuation differed by no more than 10 HU between truly and virtually unenhanced scans overall, these differences varied by organ and were large in individual patients. Paired comparisons of truly and virtually unenhanced measurements differed significantly for liver, spleen, pancreas, kidneys, and aortic blood pool (p < 0.001 for all comparisons), but paired comparisons of truly unenhanced and individually organ-corrected measurements did not differ when organ-and habitus-based correction strategies were applied (p > 0.38 for all comparisons). CONCLUSION. Habitus and organ enhancement influence virtually unenhanced imaging and should be incorporated into spectral subtraction algorithms.
引用
收藏
页码:W558 / W564
页数:7
相关论文
共 28 条
[1]
Bell Helge, 1994, Tidsskrift for den Norske Laegeforening, V114, P1697
[2]
Calcified vascular plaque specimens: Assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom [J].
Boll, Daniel T. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Mirza, Rizvan A. ;
Fleiter, Thorsten R. .
RADIOLOGY, 2008, 249 (01) :119-126
[3]
Renal Stone Assessment with Dual-Energy Multidetector CT and Advanced Postprocessing Techniques: Improved Characterization of Renal Stone Composition-Pilot Study [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Simmons, W. Neal ;
Pierre, Sean A. ;
Preminger, Glenn M. .
RADIOLOGY, 2009, 250 (03) :813-820
[4]
Prevalence of adrenal incidentaloma in a contemporary computerized tomography series [J].
Bovio, S. ;
Cataldi, A. ;
Reimondo, G. ;
Sperone, P. ;
Novello, S. ;
Berruti, A. ;
Borasio, P. ;
Fava, C. ;
Dogliotti, L. ;
Scagliotti, G. V. ;
Angeli, A. ;
Terzolo, M. .
JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2006, 29 (04) :298-302
[5]
EFFICACY OF HEPATIC COMPUTED-TOMOGRAPHY TO DETECT IRON OVERLOAD IN CHRONIC-HEMODIALYSIS [J].
CECCHIN, E ;
DEMARCHI, S ;
QUERIN, F ;
MARIN, MG ;
FIORENTINO, R ;
TESIO, F .
KIDNEY INTERNATIONAL, 1990, 37 (03) :943-950
[6]
HEPATIC IRON OVERLOAD - DIAGNOSIS AND QUANTIFICATION BY NONINVASIVE IMAGING [J].
CHEZMAR, JL ;
NELSON, RC ;
MALKO, JA ;
BERNARDINO, ME .
GASTROINTESTINAL RADIOLOGY, 1990, 15 (01) :27-31
[7]
Intercomparison of methods for image quality characterization. II. Noise power spectrum [J].
Dobbins, James T., III ;
Samei, Ehsan ;
T Ranger, Nicole ;
Chen, Ying .
MEDICAL PHYSICS, 2006, 33 (05) :1466-1475
[8]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[9]
Single-Phase Dual- Energy CT Allows for Characterization of Renal Masses as Benign or Malignant [J].
Graser, Anno ;
Becker, Christoph R. ;
Staehler, Michael ;
Clevert, Dirk A. ;
Macari, Michael ;
Arndt, Niko ;
Nikolaou, Konstantin ;
Sommer, Wieland ;
Stief, Christian ;
Reiser, Maximilian F. ;
Johnson, Thorsten R. C. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :399-405
[10]
Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440