Retrospective intermodality registration techniques for images of the head: Surface-based versus volume-based

被引:97
作者
West, J
Fitzpatrick, JM
Wang, MY
Dawant, BM
Maurer, CR
Kessler, RM
Maciunas, RJ
机构
[1] Vanderbilt Univ, Dept Comp Sci, Nashville, TN 37212 USA
[2] Vanderbilt Univ, Dept Elect & Comp Engn, Nashville, TN 37212 USA
[3] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37212 USA
[4] Vanderbilt Univ, Dept Radiol, Nashville, TN 37212 USA
[5] Vanderbilt Univ, Dept Neurol Surg, Nashville, TN 37212 USA
关键词
computed tomography; image registration; magnetic resonance; positron emission tomography; surface-based versus volume-based;
D O I
10.1109/42.759119
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The primary objective of this slurry is to perform a blinded evaluation of two groups of retrospective image registration techniques, using as a gold standard a prospective marker-based registration method, and to compare the performance of one group with the other. These techniques have already been evaluated individually [27], In this paper, however, me End that by grouping the techniques as volume based or surface based, we can make some interesting conclusions which were not visible in the earlier study, In order to ensure blindness, all retrospective registrations were performed by participants who had no knowledge of the gold-standard results until after their results had been submitted, Image volumes of three modalities: X-ray computed tomography (CT), magnetic resonance (MR), and positron emission tomography (PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted.. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/or From PET to MR, These investigators communicated their transformations, again via the Internet, to Vanderbilt, where the accuracy of each registration was evaluated, In this evaluation, the accuracy is measured at multiple volumes of interest (VOI's). Our results indicate that the volume-based techniques in this study tended to give substantially more accurate and reliable results than the surface-based ones for the CT-to-MR registration tasks, and slightly more accurate results for the PET-to-MR tasks, Analysis of these results revealed that the rotational component of error was more pronounced for the surface-based group, It was also apparent that all of the registration techniques we examined have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 29 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]  
Baxter BS, 1982, STANDARD FORMAT DIGI
[3]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[4]  
COLLIGNON A, 1995, COMP IMAG VIS, V3, P263
[5]   A STANDARD PROTOCOL FOR THE EXCHANGE OF NUCLEAR-MEDICINE IMAGE FILES [J].
CRADDUCK, TD ;
BAILEY, DL ;
HUTTON, BF ;
DECONNINCK, F ;
BUSEMANNSOKOLE, E ;
BERGMANN, H ;
NOELPP, U .
NUCLEAR MEDICINE COMMUNICATIONS, 1989, 10 (10) :703-713
[6]   Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain [J].
Fitzpatrick, JM ;
Hill, DLG ;
Shyr, Y ;
West, J ;
Studholme, C ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (04) :571-585
[7]  
Hemler P F, 1995, J Image Guid Surg, V1, P35, DOI 10.1002/(SICI)1522-712X(1995)1:1<35::AID-IGS6>3.0.CO
[8]  
2-N
[9]  
Jacq JJ, 1996, LECT NOTES COMPUT SC, V1131, P53, DOI 10.1007/BFb0046935
[10]  
Jiang H, 1992, VISUALIZATION BIOMED, P196