Glucose oxidase polyion complex-bilayer membrane for elimination of electroactive interferents in amperometric glucose sensor

被引:71
作者
Mizutani, F [1 ]
Sato, Y [1 ]
Hirata, Y [1 ]
Sawaguchi, T [1 ]
Yabuki, S [1 ]
机构
[1] Natl Inst Biosci & Human Technol, Tsukuba, Ibaraki 3058566, Japan
关键词
amperometry; enzyme electrode; glucose; polyion complex; permselective membrane; elimination of interferents;
D O I
10.1016/S0003-2670(98)00003-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric glucose-sensing electrode was prepared by immobilizing glucose oxidase (GOx) on a polyion complex membrane. First, a monolayer of 3-mercaptopropionic acid (MPA) was made on the surface of a gold electrode by immersing it in an ethanol solution containing MPA. Aqueous solutions of poly-L-lysine and poly-4-styrenesulfonate were successively placed on the electrode surface and allowed to dry. A GOx layer was then formed on the poly-L-lysine/poly-4-styrenesulfonate-complex layer by crosslinking the enzyme by the addition of a glutaraldehyde solution. The polyion complex layer was effective for eliminating electrochemical interferents such as L-ascorbic acid, uric acid and acetaminophen. whereas the hydrogen peroxide produced through the GOx-catalyzed reaction permeated rapidly through the layer. This resulted in a rapid response (100% response in <5 s) with a low interference level (e.g., the ratio of response for L-ascorbic acid to that for the same concentration of glucose was 0.07). The electrode was applied to the assay of glucose in beverages and sera, and could be used for more than two months, (C) 1998 Elsevier Science :B.V.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 33 条
  • [1] ALVEREZICAZA M, 1993, ANAL CHEM, V65, pA525
  • [2] [Anonymous], ENCY POLYM SCI ENG
  • [3] [Anonymous], 1969, ENCY POLYM SCI TECHN
  • [4] SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE
    CARDOSI, MF
    BIRCH, SW
    [J]. ANALYTICA CHIMICA ACTA, 1993, 276 (01) : 69 - 74
  • [5] INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM
    CENTONZE, D
    GUERRIERI, A
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09): : 729 - 733
  • [6] PERMEATION OF SOLUTES THROUGH AN ELECTROPOLYMERIZED ULTRATHIN POLY-O-PHENYLENEDIAMINE FILM USED AS AN ENZYME-ENTRAPPING MEMBRANE
    CENTONZE, D
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    [J]. ELECTROANALYSIS, 1994, 6 (5-6) : 423 - 429
  • [7] USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS
    EMR, SA
    YACYNYCH, AM
    [J]. ELECTROANALYSIS, 1995, 7 (10) : 913 - 923
  • [8] ELECTROPOLYMERIZED FILMS TO PREVENT INTERFERENCES AND ELECTRODE FOULING IN BIOSENSORS
    GEISE, RJ
    ADAMS, JM
    BARONE, NJ
    YACYNYCH, AM
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) : 151 - 160
  • [9] CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD
    HARRISON, DJ
    TURNER, RFB
    BALTES, HP
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (19) : 2002 - 2007
  • [10] CHARACTERIZATION OF POLY-L-LYSINE ADSORPTION ONTO ALKANETHIOL-MODIFIED GOLD SURFACES WITH POLARIZATION-MODULATION FOURIER-TRANSFORM INFRARED-SPECTROSCOPY AND SURFACE-PLASMON RESONANCE MEASUREMENTS
    JORDAN, CE
    FREY, BL
    KORNGUTH, S
    CORN, RM
    [J]. LANGMUIR, 1994, 10 (10) : 3642 - 3648