3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia

被引:43
作者
Britz, H. M.
Jokihaara, J. [2 ]
Leppanen, O. V. [3 ]
Jarvinen, T. [3 ]
Cooper, D. M. L. [1 ]
机构
[1] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Tampere, FIN-33101 Tampere, Finland
关键词
Cortical bone; cortical porosity; histology; micro-CT; rat; synchrotron; MICROCOMPUTED TOMOGRAPHY; MORPHOMETRIC-ANALYSIS; COMPUTED TOMOGRAPHY; CANCELLOUS BONE; TRABECULAR BONE; MICROSTRUCTURE; SECTIONS; SCAFFOLDS; THICKNESS; SIZE;
D O I
10.1111/j.1365-2818.2010.03381.x
中图分类号
TH742 [显微镜];
学科分类号
080401 [精密仪器及机械];
摘要
P>Although micro-computed tomography (micro-CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro-CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron-based micro-CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro-CT. Tibiae (n = 10) from 30-week-old female Sprague-Dawley rats were imaged with micro-CT (3 mu m nominal resolution) and sequential ground sections were then prepared. Bland-Altman plots were constructed to compare per cent porosity and mean canal diameter from micro-CT (3D) versus histology (2D). The mean difference or bias (histology - micro-CT; +/- 95% confidence interval) for per cent porosity was found to be -0.15% (+/- 2.57%), which was not significantly different from zero (P = 0.720). Canal diameter had a bias (+/- 95% confidence interval) of -5.73 mu m (+/- 4.02 mu m) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro-CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro-CT. Thus, although higher resolution, such as that available from synchrotron micro-CT, may ultimately be required for precise geometric measurements, desktop micro-CT - which is far more accessible - is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 36 条
[1]
MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]
Three-dimensional characterization of cortical bone microstructure by microcomputed tomography: validation with ultrasonic and microscopic measurements [J].
Basillais, Armelle ;
Bensamoun, Sabine ;
Chappard, Christine ;
Brunet-Imbault, Barbara ;
Lemineur, Gerald ;
Ilharreborde, Brice ;
Tho, Marie-Christine Ho Ba ;
Benhamou, Claude-Laurent .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (02) :141-148
[3]
Age does not influence the bone response to treadmill exercise in female rats [J].
Bennell, KL ;
Khan, KM ;
Warmington, S ;
Forwood, MR ;
Coleman, BD ;
Bennett, MB ;
Wark, JD .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (12) :1958-1965
[4]
Bernhardt R, 2004, Eur Cell Mater, V7, P42
[5]
Risedronate Reduces Intracortical Porosity in Women With Osteoporosis [J].
Borah, Babul ;
Dufresne, Tom ;
Nurre, Joe ;
Phipps, Roger ;
Chmielewski, Paula ;
Wagner, Leigh ;
Lundy, Mark ;
Bouxsein, Mary ;
Zebaze, Roger ;
Seeman, Ego .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (01) :41-47
[6]
Cortical bone in the human femoral neck: Three-dimensional appearance and porosity using synchrotron radiation [J].
Bousson, V ;
Peyrin, F ;
Berot, C ;
Hausard, M ;
Sautet, A ;
Laredo, JD .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (05) :794-801
[7]
FATIGUE LIFE OF COMPACT BONE .2. EFFECTS OF MICROSTRUCTURE AND DENSITY [J].
CARTER, DR ;
HAYES, WC ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICS, 1976, 9 (04) :211-+
[8]
Age- and gender-dependent changes in three-dimensional microstructure of cortical and trabecular bone at the human femoral neck [J].
Chen, H. ;
Zhou, X. ;
Shoumura, S. ;
Emura, S. ;
Bunai, Y. .
OSTEOPOROSIS INTERNATIONAL, 2010, 21 (04) :627-636
[9]
THE 3-DIMENSIONAL ANATOMY OF HAVERSIAN SYSTEMS [J].
COHEN, J ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (02) :419-434
[10]
Cooper D. M. L., 2003, Anatomical Record, V274B, P169, DOI 10.1002/ar.b.10024