Effect of membrane configuration on bench-scale MF and UF fouling experiments

被引:38
作者
Howe, Kerry J.
Marwah, Ashish
Chiu, Kuang-Ping
Adham, Samer S.
机构
[1] Univ New Mexico, Albuquerque, NM 87131 USA
[2] Boyle Engn Corp, Ontario, CA 91762 USA
[3] MHW Amer Inc, Pasadena, CA 91101 USA
关键词
microfiltration; ultrafiltration; hollow fiber; bench testing;
D O I
10.1016/j.watres.2007.05.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hollow fiber and flat sheet membranes were compared in side-by-side bench-scale experiments to evaluate whether the configuration has an impact on the rate of membrane fouling. Both microfiltration (MF) and ultrafiltration (UF) membranes were evaluated. In general, flat sheet membranes fouled more rapidly than hollow fiber membranes. Pretreatment such as coagulation generally affected both configurations similarly, but in some cases coagulation reduced fouling on hollow fiber membranes but increased fouling on flat sheet membranes. Prefiltration to remove foulants above 1 pm in size had a consistent effect on both configurations. A bench-scale apparatus employing a single-fiber module that allows testing over multiple filter runs with integral backwashing capabilities was demonstrated to provide more detailed information about fouling, which can be applied to full-scale applications. When bench-scale tests are to be used to screen treatment options for full-scale applications, the use of a backwashable hollow fiber system is recommended. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3842 / 3849
页数:8
相关论文
共 20 条
[1]  
Adham S, 2006, OPTIMIZATION MEMBRAN, V91111
[2]  
[Anonymous], 1994, STANDARD METHODS EXA, V16th, DOI DOI 10.1-10.47
[3]  
Chang YJ, 1996, J AM WATER WORKS ASS, V88, P74
[4]  
Crittenden J.C., 2005, Water treatment principles and design
[5]   Role of membrane surface morphology in colloidal fouling of cellulose acetate and composite aromatic polyamide reverse osmosis membranes [J].
Elimelech, M ;
Zhu, XH ;
Childress, AE ;
Hong, SK .
JOURNAL OF MEMBRANE SCIENCE, 1997, 127 (01) :101-109
[6]  
Escobar IC, 2005, J AM WATER WORKS ASS, V97, P79
[7]   Blocking of capillaries as fouling mechanism for dead-end ultrafiltration [J].
Heijman, S. G. J. ;
Vantieghem, M. ;
Raktoe, S. ;
Verberk, J. Q. J. C. ;
van Dijk, J. C. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 287 (01) :119-125
[8]  
HERMIA J, 1982, T I CHEM ENG-LOND, V60, P183
[9]   Effect of coagulation on the size of MF and UF membrane foulants [J].
Howe, Kerry J. ;
Marwah, Ashish ;
Chiu, Kuang-Ping ;
Adham, Samer S. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (24) :7908-7913
[10]  
Howe KJ, 2006, J AM WATER WORKS ASS, V98, P133