Hypersensitivity reactions associated with endovascular devices

被引:92
作者
Honari, Golara [2 ]
Ellis, Stephen G. [3 ,4 ]
Wilkoff, Bruce L. [3 ,4 ,5 ,6 ]
Aronica, Mark A. [3 ,5 ,6 ,7 ]
Svensson, Lars G. [8 ]
Taylor, James S. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Dermatol, Sect Ind Dermatol, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Dermatol, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Lerner Coll Med, Cleveland, OH 44106 USA
[4] Cleveland Clin, Sones Cardiac Catheterizat Labs, Dept Cardiovasc Med, Sect Cardiac Pacemakers & Electrophysiol, Cleveland, OH 44106 USA
[5] Cleveland Clin, Dept Pulm Allergy & Crit Care Med, Cleveland, OH 44106 USA
[6] Cleveland Clin, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44106 USA
[7] Cleveland Clin Fdn, Dept Pathobiol, Cleveland, OH 44195 USA
[8] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
关键词
allergic contact dermatitis; Amplatzer; cardioverter defibrillators; endovascular devices; hypersensitivity; implantable; metal allergy; pacemaker; patch test; patent foramen ovale occluder; stent restenosis;
D O I
10.1111/j.1600-0536.2008.01351.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Allergic reactions to endoprostheses are uncommon and reported in association with orthopaedic, dental, endovascular and other implanted devices. Hypersensitivity reactions to the biomaterials used in endovascular prostheses are among the infrequent reactions that may lead to local or systemic complications following cardiovascular therapeutic interventions. This article reviews potential immunotoxic effects of commonly used biomaterials. Reports of putative hypersensitivity reactions to endovascular devices, including coronary stents, perforated foramen occluders, pacemakers and implantable cardioverter defibrillators are also reviewed.
引用
收藏
页码:7 / 22
页数:16
相关论文
共 111 条
[1]   PACEMAKER CONTACT SENSITIVITY - CLINICAL RECOGNITION AND MANAGEMENT [J].
ABDALLAH, HI ;
BALSARA, RK ;
ORIORDAN, AC .
ANNALS OF THORACIC SURGERY, 1994, 57 (04) :1017-1018
[2]  
Alonge L, 2003, INFORM PHYS SUBACUTE
[3]  
ALONGE L, 2003, UPDATED INFORM PHYS
[4]  
ALONGE L, 2004, FINAL UPDATE INFORM
[5]   CUTANEOUS REACTION TO AN EPOXY-COATED PACEMAKER [J].
ANDERSEN, KE .
ARCHIVES OF DERMATOLOGY, 1979, 115 (01) :97-98
[6]  
[Anonymous], 2004, Biomaterials Science-An Introduction to Materials in Medicine
[7]  
[Anonymous], 2000, FDA DOC AMPL SUMM SA
[8]   A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents [J].
Babapulle, MN ;
Joseph, L ;
Bélisle, P ;
Brophy, JM ;
Eisenberg, MJ .
LANCET, 2004, 364 (9434) :583-591
[9]   Silicone gel breast implants and connective tissue disease - A comprehensive review [J].
Bar-Meir, E ;
Eherenfeld, M ;
Shoenfeld, Y .
AUTOIMMUNITY, 2003, 36 (04) :193-197
[10]   XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent [J].
Beijk, Marcel A. M. ;
Piek, Jon J. .
EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (01) :11-21