Real-time resampling in Fourier domain optical coherence tomography using a graphics processing unit

被引:66
作者
Van der Jeught, Sam [1 ]
Bradu, Adrian [1 ]
Podoleanu, Adrian Gh [1 ]
机构
[1] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
基金
英国工程与自然科学研究理事会;
关键词
Fourier domain optical coherence tomography; graphics processing unit;
D O I
10.1117/1.3437078
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Fourier domain optical coherence tomography (FD-OCT) requires either a linear-in-wavenumber spectrometer or a computationally heavy software algorithm to recalibrate the acquired optical signal from wavelength to wavenumber. The first method is sensitive to the position of the prism in the spectrometer, while the second method drastically slows down the system speed when it is implemented on a serially oriented central processing unit. We implement the full resampling process on a commercial graphics processing unit (GPU), distributing the necessary calculations to many stream processors that operate in parallel. A comparison between several recalibration methods is made in terms of performance and image quality. The GPU is also used to accelerate the fast Fourier transform (FFT) and to remove the background noise, thereby achieving full GPU-based signal processing without the need for extra resampling hardware. A display rate of 25 frames/sec is achieved for processed images (1024 x 1024 pixels) using a line-scan charge-coupled device (CCD) camera operating at 25.6 kHz. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3437078]
引用
收藏
页数:3
相关论文
共 6 条
[1]
Linear-wavenumber spectrometer for high-speed spectral-domain optical coherence tomography [J].
Gelikonov, V. M. ;
Gelikonov, G. V. ;
Shilyagin, P. A. .
OPTICS AND SPECTROSCOPY, 2009, 106 (03) :459-465
[2]
Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[3]
Ruijters Daniel, 2008, Proceedings of the Tenth IASTED International Conference on Computer Graphics and Imaging, P117
[4]
Real-time digital signal processing-based optical coherence tomography and Doppler optical coherence tomography [J].
Schaefer, AW ;
Reynolds, JJ ;
Marks, DL ;
Boppart, SA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (01) :186-190
[5]
A practical approach to eliminate autocorrelation artefacts for volume-rate spectral domain optical coherence tomography [J].
Wang, Ruikang K. ;
Ma, Zhenhe .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12) :3231-3239
[6]
Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit [J].
Watanabe, Yuuki ;
Itagaki, Toshiki .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (06)