The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses

被引:93
作者
Heisel, C
Silva, M
Skipor, AK
Jacobs, JJ
Schmalzried, TP
机构
[1] Orthoped Hosp, Joint Replacement Inst, Los Angeles, CA 90007 USA
[2] Rush Arthrit & Orthopaed Inst, Chicago, IL USA
关键词
D O I
10.2106/JBJS.D.01820
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total hip replacements with metal-on-metal bearings are frequently implanted in young, active patients. The relationship between patient activity and cobalt and chromium ion levels has not been investigated, to our knowledge. Methods: Seven patients with well-functioning metal-on-metal bearing hip prostheses and one control subject (no implants), all with normal renal function, were monitored during a two-week-long activity protocol. Lower-extremity activity was continuously assessed with use of a computerized, two-dimensional accelerometer. During the first week, the subjects were requested to limit physical activity. The subjects then completed an hour-long treadmill test followed by a week in which they were encouraged to be as physically active as practically possible. Serum levels of cobalt and chromium ions and urine levels of chromium were assessed at ten time-points during these two weeks. Results: Regardless of activity, the serum ion levels for a given patient were essentially constant and no correlation was found between patient activity and serum levels of cobalt or chromium, or urine levels of chromium. A mean increase in activity of 28% during the week of high-intensity activity was associated with a mean decrease of 2.7% in the serum cobalt level and a mean increase of 2.0% in the serum chromium level. During the treadmill test, a mean increase in activity of 1621% was associated with a mean increase of 3.0% in the serum cobalt level and a mean increase of 0.8% in the serum chromium level. These results fall within the variability for the measurement accuracy of these tests. Conclusions: For these patients, serum cobalt and chromium ion levels were not acutely affected by patient activity. Periodic measurements of serum ion levels could be used to monitor the tribologic (lubrication, friction, and wear) performance of a metal-on-metal bearing without adjusting for patient activity. Additional research is needed into the kinetics of ion production, transport, and excretion.
引用
收藏
页码:781 / 787
页数:7
相关论文
共 36 条
[1]  
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS297
[2]   Metal-on-metal bearing with THA and chronic renal failure. [J].
Brodner, V ;
Grohs, JG ;
Bitzan, P ;
Meisinger, V ;
Kovarik, J ;
Kotz, R .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (05) :425-429
[3]  
BRODNER W, 2003, 2 INT C MET MET HIP
[4]   Autopsy analysis thirty years after metal-on-metal total hip replacement - A case report [J].
Campbell, P ;
Urban, RM ;
Catelas, I ;
Skipor, AK ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2218-2222
[5]  
CATELAS I, 2001, THESIS MCGILL U MONT, P149
[6]  
Chan FW, 1999, CLIN ORTHOP RELAT R, P10
[7]  
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO
[8]  
2-D
[9]  
Doorn PF, 1996, CLIN ORTHOP RELAT R, pS187
[10]   Total hip arthroplasty with use of the metasul metal-on-metal articulation - Four to seven-year results [J].
Dorr, LD ;
Wang, ZI ;
Longjohn, DB ;
Dubois, B ;
Murken, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06) :789-798