Quantification of intensity variations in functional MR images using rotated principal components

被引:69
作者
Backfrieder, W
Baumgartner, R
Samal, M
Moser, E
Bergmann, H
机构
[1] UNIV VIENNA, NMR GRP, DEPT MED PHYS, A-1010 VIENNA, AUSTRIA
[2] UNIV VIENNA, MR UNIT, A-1010 VIENNA, AUSTRIA
[3] CHARLES UNIV, FAC MED 1, INST NUCL MED, PRAGUE, CZECH REPUBLIC
关键词
D O I
10.1088/0031-9155/41/8/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In functional MRI (fMRI), the changes in cerebral haemodynamics related to stimulated neural brain activity are measured using standard clinical MR equipment. Small intensity variations in fMRI data have to be detected and distinguished from non-neural effects by careful image analysis. Based on multivariate statistics we describe an algorithm involving oblique rotation of the most significant principal components for an estimation of the temporal and spatial distribution of the stimulated neural activity over the whole image matrix. This algorithm takes advantage of strong local signal variations. A mathematical phantom was designed to generate simulated data for the evaluation of the method. In simulation experiments, the potential of the method to quantify small intensity changes, especially when processing data sets containing multiple sources of signal variations, was demonstrated. In vivo fMRI data collected in both visual and motor stimulation experiments were analysed, showing a proper location of the activated cortical regions within well known neural centres and an accurate extraction of the activation time profile. The suggested method yields accurate absolute quantification of in vivo brain activity without the need of extensive prior knowledge and user interaction.
引用
收藏
页码:1425 / 1438
页数:14
相关论文
共 25 条
  • [1] BACKFRIEDER W, 1995, MED PHYSIK 95, P336
  • [2] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [3] BAUMGARTNER R, 1995, P SMR ESMRMB 3 JOINT, P846
  • [4] BENALI H, 1995, COMP IMAG VIS, V3, P311
  • [5] FRISTON KJ, 1995, HUMAN BRAIN MAPPING, V2, P69
  • [6] MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS
    GLOVER, GH
    LEE, AT
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 624 - 635
  • [7] Gomiscek G., 1993, MAGMA, V1, P109, DOI 10.1007/BF01769410
  • [8] HAACKE EM, 1995, IN PRESS MAGN RESON
  • [10] HOUSTON AS, 1985, INFORMATION PROCESSI, P177