A Blind Deconvolution Approach for Improving the Resolution of Cryo-EM Density Maps

被引:10
作者
Hirsch, Michael [2 ]
Schoelkopf, Bernhard [2 ]
Habeck, Michael [1 ,2 ]
机构
[1] Max Planck Inst Dev Biol, D-72076 Tubingen, Germany
[2] Max Planck Inst Biol Cybernet, Tubingen, Germany
关键词
algorithms; machine learning; INFORMATION; IMAGE;
D O I
10.1089/cmb.2010.0264
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron microscopy (cryo-EM) plays an increasingly prominent role in structure elucidation of macromolecular assemblies. Advances in experimental instrumentation and computational power have spawned numerous cryo-EM studies of large biomolecular complexes resulting in the reconstruction of three-dimensional density maps at intermediate and low resolution. In this resolution range, identification and interpretation of structural elements and modeling of biomolecular structure with atomic detail becomes problematic. In this article, we present a novel algorithm that enhances the resolution of intermediateand low-resolution density maps. Our underlying assumption is to model the low-resolution density map as a blurred and possibly noise-corrupted version of an unknown high-resolution map that we seek to recover by deconvolution. By exploiting the nonnegativity of both the high-resolution map and blur kernel, we derive multiplicative updates reminiscent of those used in nonnegative matrix factorization. Our framework allows for easy incorporation of additional prior knowledge such as smoothness and sparseness, on both the sharpened density map and the blur kernel. A probabilistic formulation enables us to derive updates for the hyperparameters; therefore, our approach has no parameter that needs adjustment. We apply the algorithm to simulated three-dimensional electron microscopic data. We show that our method provides better resolved density maps when compared with B-factor sharpening, especially in the presence of noise. Moreover, our method can use additional information provided by homologous structures, which helps to improve the resolution even further.
引用
收藏
页码:335 / 346
页数:12
相关论文
共 22 条
[1]   Low-resolution crystallography is coming of age [J].
Brunger, AT .
STRUCTURE, 2005, 13 (02) :171-172
[2]   Electron cryomicroscopy of biological machines at subnanometer resolution [J].
Chiu, W ;
Baker, ML ;
Jiang, W ;
Dougherty, M ;
Schmid, MF .
STRUCTURE, 2005, 13 (03) :363-372
[3]   Considerations for the refinement of low-resolution crystal structures [J].
DeLaBarre, Byron ;
Brunger, Axel T. .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2006, 62 :923-932
[4]   Sharpening high resolution information in single particle electron cryomicroscopy [J].
Fernandez, J. J. ;
Luque, D. ;
Caston, J. R. ;
Carrascosa, J. L. .
JOURNAL OF STRUCTURAL BIOLOGY, 2008, 164 (01) :170-175
[5]   Single-particle imaging of macromolecules by cryo-electron microscopy [J].
Frank, J .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 2002, 31 :303-319
[6]   The atomic structure of the bluetongue virus core [J].
Grimes, JM ;
Burroughs, JN ;
Gouet, P ;
Diprose, JM ;
Malby, R ;
Ziéntara, S ;
Mertens, PPC ;
Stuart, DI .
NATURE, 1998, 395 (6701) :470-478
[7]   Bridging the information gap: Computational tools for intermediate resolution structure interpretation [J].
Jiang, W ;
Baker, ML ;
Ludtke, SJ ;
Chiu, W .
JOURNAL OF MOLECULAR BIOLOGY, 2001, 308 (05) :1033-1044
[8]   Augmented Tikhonov regularization [J].
Jin, Bangti ;
Zou, Jun .
INVERSE PROBLEMS, 2009, 25 (02)
[9]   An improved method for deconvolving a positive image [J].
Johnston, RA ;
Connolly, TJ ;
Lane, RG .
OPTICS COMMUNICATIONS, 2000, 181 (4-6) :267-278
[10]   Blind image deconvolution [J].
Kundur, D ;
Hatzinakos, D .
IEEE SIGNAL PROCESSING MAGAZINE, 1996, 13 (03) :43-64