Modelling of cross-flow membrane contactors: Mass transfer with chemical reactions

被引:72
作者
Dindore, VY
Brilman, DWF
Versteeg, GE
机构
[1] Univ Twente, Fac Chem Technol, NL-7500 AE Enschede, Netherlands
[2] Sasol Technol Netherlands BV, NL-7522 NB Enschede, Netherlands
关键词
hollow fiber membranes; membrane contactors; gas treating; cross-flow; modelling;
D O I
10.1016/j.memsci.2005.01.042
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Conventionally, carbon dioxide and hydrogen sulphide are absorbed using aqueous alkanolamines or carbonate solution in column type of equipment. However, in view of the unparallel advantages offered, the use of microporous hollow fiber membrane modules is an attractive alternative. In the present study application of cross-flow membrane contactors for absorption of these gases using aqueous potassium carbonate as a solvent is explored. The carbon dioxide and hydrogen sulphide absorption into aqueous solutions carbonate involves complex chemical reactions. The effect of these chemical reactions on the absorption into a liquid flowing though a hollow fiber membrane may not be described using conventional mass transfer models like e.g. the penetration or surface renewal model due to the lack of a well defined liquid phase bulk and the presence of a laminar velocity profile in the mass transfer zone. Moreover, in the case of cross-flow membrane contactors, the concentrations of both fluids, inside and outside the fibers, vary in both directions i.e. in the direction of flow,and in the direction normal to the flow. Hence the theoretical analysis of the cross-flow membrane contactor is more complicated. To describe the effect of the chemical reaction on the absorption rate in the cross-flow hollow fiber contactor, a detailed mathematical model was developed using first principles. A complete scheme of the reversible ionic reactions and equilibria involved was implemented in the model to describe the solute uptake. The experiments were carried out study the effects various parameters such as gas and liquid velocities, bulk concentrations of solute gas and liquid phase reactant. The theoretical predictions were compared with experimental results. An excellent match between experimental results and model predictions was obtained. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:275 / 289
页数:15
相关论文
共 35 条
[1]   HYDROGEN SULPHIDE CHEMICAL ABSORPTION [J].
ASTARITA, G ;
GIOIA, F .
CHEMICAL ENGINEERING SCIENCE, 1964, 19 (12) :963-971
[2]  
Astarita G., 1967, MASS TRANSFER CHEM R
[3]  
Bhat RDV, 2000, CHEM ENG J, V76, P127
[4]   THE SOLUBILITY OF HYDROGEN-SULFIDE IN WATER FROM 0-DEGREES-C TO 90-DEGREES-C AND PRESSURES TO 1-MPA [J].
CARROLL, JJ ;
MATHER, AE .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1989, 53 (06) :1163-1170
[5]   Analysis on a hydrophobic hollow-fiber membrane absorber and experimental observations of CO2 removal by enhanced absorption [J].
Chun, MS ;
Lee, KH .
SEPARATION SCIENCE AND TECHNOLOGY, 1997, 32 (15) :2445-2466
[6]   CORRELATION FOR THE ESTIMATION OF GAS-LIQUID DIFFUSIVITY [J].
DIAZ, M ;
VEGA, A ;
COCA, J .
CHEMICAL ENGINEERING COMMUNICATIONS, 1987, 52 (4-6) :271-281
[7]   CO2 absorption at elevated pressures using a hollow fiber membrane contactor [J].
Dindore, VY ;
Brilman, DWF ;
Feron, PHM ;
Versteeg, GF .
JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) :99-109
[8]   Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors [J].
Dindore, VY ;
Brilman, DWF ;
Geuzebroek, FH ;
Versteeg, GF .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) :133-145
[9]  
DINDORE VY, 2005, IN PRESS J MEMBR SCI
[10]  
DINDORE VY, 2005, CHEM ENG RES DES, V83, P1