Automated high-frequency posture sampling for ergonomic assessment of laparoscopic surgery

被引:31
作者
Person, JG
Hodgson, AJ [1 ]
Nagy, AG
机构
[1] Univ British Columbia, Dept Mech Engn, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Dept Surg, Vancouver, BC V6T 1Z4, Canada
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 2001年 / 15卷 / 09期
关键词
ergonomics; simulation validation; motion analysis; training; laparoscopic surgery;
D O I
10.1007/s004640080155
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Despite widespread acknowledgement that strain injuries do occur to surgeons, ergonomic assessments in minimally invasive surgery are comparatively rare. Current assessment techniques rely on labor-intensive manual recording techniques, so there is a need for an automated system. Methods: We used an optoelectronic measurement system to make postural measurements at frequencies of similar to5 Hz and then converted these measurements to ergonomic stress scores using a modified Rapid Upper Limb Assessment (RULA) method. Results: We successfully recorded postures at least once per second during 96% of the time the surgeon was performing tissue manipulation tasks. We found that the ergonomic stress scores were comparatively high throughout the procedure, particularly for the wrist. Conclusion: An automated high-frequency postural measurement system is feasible for making ergonomic assessments in an intraoperative setting. Such a system will also be a critical component in validating surgical simulations for use in training and credentialing surgeons and in designing and evaluating equipment.
引用
收藏
页码:997 / 1003
页数:7
相关论文
共 20 条
[1]   3-DIMENSIONAL KINEMATICS OF GLENOHUMERAL ELEVATION [J].
AN, KN ;
BROWNE, AO ;
KORINEK, S ;
TANAKA, S ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (01) :143-149
[2]  
ANGLIN C, 1993, THESIS U BRIT COLUMB
[3]   A comparison of surgeons' posture during laparoscopic and open surgical procedures [J].
Berguer, R ;
Rab, GT ;
AbuGhaida, H ;
Alarcon, A ;
Chung, J .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (02) :139-142
[4]   Ergonomic problems associated with laparoscopic surgery [J].
Berguer, R ;
Forkey, DL ;
Smith, WD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (05) :466-468
[5]   An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper [J].
Berguer, R ;
Gerber, S ;
Kilpatrick, G ;
Beckley, D .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1998, 12 (06) :805-808
[6]   Development and evaluation of a microprocessor-based ergonomic dosimeter for evaluating carpentry tasks [J].
Bhattacharya, A ;
Warren, J ;
Teuschler, J ;
Dimov, M ;
Medvedovic, M ;
Lemasters, G .
APPLIED ERGONOMICS, 1999, 30 (06) :543-553
[7]   Development of a model for training and evaluation of laparoscopic skills [J].
Derossis, AM ;
Fried, GM ;
Abrahamowicz, M ;
Sigman, HH ;
Barkun, JS ;
Meakins, JL .
AMERICAN JOURNAL OF SURGERY, 1998, 175 (06) :482-487
[8]   Rocker handle for endoscopic needle drivers - Technical and ergonomic evaluation by infrared motion analysis system [J].
Emam, TA ;
Frank, TG ;
Hanna, GB ;
Stockham, G ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (07) :658-661
[9]   POSTURAL STRESS-ANALYSIS IN INDUSTRY [J].
GENAIDY, AM ;
ALSHEDI, AA ;
KARWOWSKI, W .
APPLIED ERGONOMICS, 1994, 25 (02) :77-87
[10]   A new method for estimating the axis of rotation and the center of rotation [J].
Halvorsen, K ;
Lesser, M ;
Lundberg, A .
JOURNAL OF BIOMECHANICS, 1999, 32 (11) :1221-1227