Control of the illegal use of clenbuterol in bovine production

被引:47
作者
Cristino, A
Ramos, F
da Silveira, MIN
机构
[1] Univ Coimbra, Fac Farm, Lab Bromatol Hidrol & Nutr, P-3000295 Coimbra, Portugal
[2] DOCQ Farmacotecn & Biofarm, INFARMED, P-1749004 Lisbon, Portugal
关键词
clenbuterol; bovine; control; hair; retina; gas chromatography-mass spectrometry;
D O I
10.1016/S0731-7085(03)00073-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study is based on a plan of collecting different matrices (hair, eye, muscle, liver and kidney) in order to define a strategy for the control of the illegal use of clenbuterol in bovine production. Of all matrices utilised, hair is recommended for the analytical control of clenbuterol in living animals, due to its being permanently available and easy to collect. The eye, or rather the retina, is the matrix which gives the most trustworthy result, after the animal slaughter, and the one that best helps in the determination of the illegal use of clenbuterol in a perspective of gradual food safety improvement. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 29 条
[1]  
[Anonymous], BETA AGONISTS THEIR
[2]  
Brambilla G, 1997, JAMA-J AM MED ASSOC, V278, P635, DOI 10.1001/jama.278.8.635
[3]   Clinical and pharmacological profile in a clenbuterol epidemic poisoning of contaminated beef meat in Italy [J].
Brambilla, G ;
Cenci, T ;
Franconi, F ;
Galarini, R ;
Macrì, A ;
Rondoni, F ;
Strozzi, M ;
Loizzo, A .
TOXICOLOGY LETTERS, 2000, 114 (1-3) :47-53
[4]   MULTI-RESIDUE ANALYSIS FOR BETA-AGONISTS IN URINE AND LIVER SAMPLES USING MIXED-PHASE COLUMNS WITH DETERMINATION BY RADIOIMMUNOASSAY [J].
COLLINS, S ;
OKEEFFE, M ;
SMYTH, MR .
ANALYST, 1994, 119 (12) :2671-2674
[5]   The hair analysis proficiency testing program of the French Society of Analytical Toxicology [J].
Deveaux, M ;
Kintz, P ;
Goullé, JP ;
Bessard, J ;
Pépin, G ;
Gosset, D .
FORENSIC SCIENCE INTERNATIONAL, 2000, 107 (1-3) :389-394
[6]  
DURSCH I, 1995, J ANIM SCI, V73, P2050
[7]   Determination of clenbuterol residues in bovine hair by using diphasic dialysis and gas chromatography mass spectrometry [J].
Fente, CA ;
Vázquez, BI ;
Franco, C ;
Cepeda, A ;
Gigosos, PG .
JOURNAL OF CHROMATOGRAPHY B, 1999, 726 (1-2) :133-139
[8]  
Garay JB, 1997, REV CLIN ESP, V197, P92
[9]   Rapid and simple determination of clenbuterol residues in retina by high-performance liquid chromatography with ultraviolet detection [J].
Gigosos, PG ;
Fernandez, TF ;
Mariz, OC ;
Sampayo, CAF ;
Abuin, CF ;
Saez, AC .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 677 (01) :167-171
[10]  
Gleixner A., 1996, P EUR 3 C VELDH, P411