Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts

被引:234
作者
Magen, HE
Howell, SM
Hull, ML
机构
[1] Univ Calif Davis, Biomed Engn Grad Grp, Davis, CA USA
[2] Univ Calif Davis, Dept Engn Mech, Davis, CA USA
[3] David Grant Med Ctr, Clin Invest Facil, Travis AFB, CA USA
关键词
D O I
10.1177/03635465990270011401
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compared the stiffness (K), yield load (YL), and slippage (SL) of six tibial fixation methods. These properties were determined from load-to-failure and cyclic tests of double-looped tendon grafts fixed to both animal and young human tissue. Tandem washers (K = 259 N/mm, YL = 1159 N, SL = 0.5 mm) and the Washerloc (K = 248 N/mm, YL = 905 N, SL = 2.0 mm) were the two best fixations. At 500 N of load, which is the estimated daily tension of an anterior cruciate ligament graft during intensive rehabilitation, slippage was significantly greater in either of the other two methods for sutures tied to a post (4.9 mm), double staples (3.3 mm), and a 20-mm spiked metal washer (3.5 mm). Interference screw fixation performed well in animal tissue (YL = 776 N), but was significantly worse in young human tissue (YL = 350 N), with 57% of the fixations failing before 500 N of load. Animal tissue should not be used to estimate the performance of interference screw fixation in human tissue. Because 57% of the interference screw fixations using human tissue failed at loads below 500 N, their ability to provide adequate fixation during intensive rehabilitation should be questioned. However, both the Washerloc and tandem washers and screws provide fixation structural properties in young human tibia that should be appropriate for intensive rehabilitation.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 22 条
[1]   ANTERIOR CRUCIATE LIGAMENT STRAIN BEHAVIOR DURING REHABILITATION EXERCISES IN-VIVO [J].
BEYNNON, BD ;
FLEMING, BC ;
JOHNSON, RJ ;
NICHOLS, CE ;
RENSTROM, PA ;
POPE, MH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (01) :24-34
[2]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[3]   Current concepts review - The science of reconstruction of the anterior cruciate ligament [J].
Frank, CB ;
Jackson, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1556-1576
[4]  
GOOD L, 1990, CLIN ORTHOP RELAT R, P190
[5]  
GOTTLIEB DJ, 1992, ORTHOP T, V16, P455
[6]   IN-VIVO FORCES IN THE ANTERIOR CRUCIATE LIGAMENT - DIRECT MEASUREMENTS DURING WALKING AND TROTTING IN A QUADRUPED [J].
HOLDEN, JP ;
GROOD, ES ;
KORVICK, DL ;
CUMMINGS, JF ;
BUTLER, DL ;
BYLSKIAUSTROW, DI .
JOURNAL OF BIOMECHANICS, 1994, 27 (05) :517-526
[7]   The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system [J].
Ishibashi, Y ;
Rudy, TW ;
Livesay, GA ;
Stone, JD ;
Fu, FH ;
Woo, SLY .
ARTHROSCOPY, 1997, 13 (02) :177-182
[8]   BIOMECHANICS OF 2 TYPES OF BONE-TENDON-BONE GRAFT FOR ACL RECONSTRUCTION [J].
LIU, SH ;
KABO, JM ;
OSTI, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (02) :232-235
[9]  
MAGEN HE, 1998, P 3 WORLD C BIOM SAP, P126
[10]   Biomechanical consequences of replacement of the anterior cruciate ligament with a patellar ligament allograft .2. Forces in the graft compared with forces in the intact ligament [J].
Markolf, KL ;
Burchfield, DM ;
Shapiro, MM ;
Cha, CW ;
Finerman, GAM ;
Slauterbeck, JL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (11) :1728-1734