A new electrochemiluminescent detection system equipped with an electrically heated carbon paste electrode for CE

被引:31
作者
Chen, Yiting
Lin, Zhenyu
Sun, Jianjun
Chen, Guonan [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fujian 350002, Peoples R China
[2] Fuzhou Univ, Minist Ket Lab Anal & Detect Technol Food Safety, Fuzhou, Peoples R China
[3] Minjiang Univ, Dept Chem Engn, Fuzhou, Peoples R China
关键词
CE; electrochemiluminescence; heated carbon paste electrode;
D O I
10.1002/elps.200700029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An electrochemiluminescent (ECL) detection system in CE with an electrically heated carbon paste electrode (CPE) was developed. This CPE could be heated by a 100 kHz alternating current (ac) generated from a function generator, and the temperature of the electrode (Te) could be controlled. To evaluate the feasibility and reliability of this system, the electrochemically generated Ru(bPY)(3)(3+)-based ECL reaction was used for detection of triethylamine (TEA) and tri-n-propylamine (TPrA). Ru(bpy)(3)(2+) was added into the separation buffer solution with precolumn mode. Effects of several important factors were investigated to acquire the optimum conditions. Under the optimum conditions, the heated electrode has been shown to provide advantages by the measurement of ECL intensity in CE at elevated Te. Compared with the conventional electrode at the room temperature, using heated CPE could improve peak shape and gain good reproducibility with lower detection limits and wider linearity ranges. Compared with the room temperature, the linear ranges and detection limits (S/N = 3) for TEA and TPrA were improved about one magnitude when the Te was 39 degrees C. In contrast, the RSD was lower than for the electrode at room temperature.
引用
收藏
页码:3250 / 3259
页数:10
相关论文
共 43 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   Hot microelectrodes [J].
Baranski, AS .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1294-1301
[3]  
Beale SC, 1998, ANAL CHEM, V70, p279R
[4]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3683, DOI 10.1002/1522-2683(200211)23:21<3683::AID-ELPS3683>3.0.CO
[5]  
2-F
[6]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3692, DOI 10.1002/1522-2683(200211)23:21<3692::AID-ELPS3692>3.0.CO
[7]  
2-J
[8]   Chemical oxidation of p-hydroxyphenylpyruvic acid in aqueous solution by capillary electrophoresis with an electrochemiluminescence detection system [J].
Chen, GN ;
Chi, YW ;
Wu, XP ;
Duan, JP ;
Li, NB .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6602-6607
[9]   Control of electron transfer kinetics at glassy carbon electrodes by specific surface modification [J].
Chen, PH ;
McCreery, RL .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3958-3965
[10]   A simple and low-cost electrochemiluminescence detector for capillary electrophoresis [J].
Chiang, MT ;
Lu, MC ;
Whang, CW .
ELECTROPHORESIS, 2003, 24 (17) :3033-3039