Evaluation of the accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector magnetic sector and time-of-flight analyzers

被引:79
作者
Barbaste, M
Halicz, L
Galy, A
Medina, B
Emteborg, H
Adams, FC
Lobinski, R
机构
[1] CNRS, UMR 5034, F-64053 Pau Pyrenees, France
[2] DGCCRF, F-33405 Talence, France
[3] Geol Survey Israel, IL-95501 Jerusalem, Israel
[4] Univ Oxford, Dept Earth Sci, Oxford OX1 3PR, England
[5] Univ Instelling Antwerp, Dept Chem, B-2610 Wilrijk, Belgium
关键词
lead; isotope ratios; ICP MS; wine;
D O I
10.1016/S0039-9140(00)00651-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different mass analysers [(quadrupole (Q), time-of-flight (TOF) and multicollector (MC) sector-field (SF)] of ions produced in an inductively coupled plasma were evaluated for the determination of lead isotope ratios in wine samples. A population of 20 wines of different origin including two reference wines from the EC Standards, Measurement and Testing Programme with concentrations varying between 7-140 mug Ph l(-1) was investigated. Wines were analyzed directly by Q ICP MS and MC ICP MS. The poor sensitivity of the TOF instrument, further aggravated by matrix signal suppression, did not allow the acquisition of data for wine samples that contained less than 50 mug l(-1) in the direct sample introduction mode. The separation and preconcentration of lead were therefore required. The precision obtained for the Pb-206/Pb-207 and Pb-208/Pb-206 were similar and equal to 0.14-2.7% for Q ICP MS, 0.04-0.17% for TOF ICP MS and 0.01-0.12% for MC ICP MS. The precision for Pb-206/Pb-204 was 0.44-5.29, 0.15-1.7, 0.08-1.6%, respectively. On the level of accuracy, the data from TOF ICP MS and MC ICP MS were in good agreement. The accuracy of Q ICP MS data was judged satisfactory in comparison with the other techniques but their poor precision Ic as a significant obstacle on the way of using these data for the determination of the geographic origin of wine, (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:307 / 317
页数:11
相关论文
共 40 条
[1]  
Adams F., 1988, INORGANIC MASS SPECT
[2]   UV-irradiation and MW-digestion pre-treatment of Port wine suitable for the determination of lead isotope ratios by inductively coupled plasma mass spectrometry [J].
Almeida, CMR ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1815-1821
[3]  
ALMEIDA CMR, 2000, IN PRESS ANAL CHIM
[4]   Measurement of lead isotope ratios in wine by ICP-MS and its applications to the determination of lead concentration by isotope dilution [J].
Augagneur, S ;
Medina, B ;
Grousset, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1149-1152
[5]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[6]  
Bandura DR, 1999, ATOM SPECTROSC, V20, P69
[7]   Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (08) :921-928
[8]   Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios [J].
Begley, IS ;
Sharp, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) :395-402
[9]   OCCURRENCE AND REDUCTION OF NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ENHANCED PRECISION IN ISOTOPE RATIO MEASUREMENT [J].
BEGLEY, IS ;
SHARP, BL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) :171-176
[10]   A new variable dispersion double-focusing plasma mass spectrometer with performance illustrated for Pb isotopes [J].
Belshaw, NS ;
Freedman, PA ;
O'Nions, RK ;
Frank, M ;
Guo, Y .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :51-58