Evaluation of the accuracy of the determination of lead isotope ratios in wine by ICP MS using quadrupole, multicollector magnetic sector and time-of-flight analyzers

被引:79
作者
Barbaste, M
Halicz, L
Galy, A
Medina, B
Emteborg, H
Adams, FC
Lobinski, R
机构
[1] CNRS, UMR 5034, F-64053 Pau Pyrenees, France
[2] DGCCRF, F-33405 Talence, France
[3] Geol Survey Israel, IL-95501 Jerusalem, Israel
[4] Univ Oxford, Dept Earth Sci, Oxford OX1 3PR, England
[5] Univ Instelling Antwerp, Dept Chem, B-2610 Wilrijk, Belgium
关键词
lead; isotope ratios; ICP MS; wine;
D O I
10.1016/S0039-9140(00)00651-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different mass analysers [(quadrupole (Q), time-of-flight (TOF) and multicollector (MC) sector-field (SF)] of ions produced in an inductively coupled plasma were evaluated for the determination of lead isotope ratios in wine samples. A population of 20 wines of different origin including two reference wines from the EC Standards, Measurement and Testing Programme with concentrations varying between 7-140 mug Ph l(-1) was investigated. Wines were analyzed directly by Q ICP MS and MC ICP MS. The poor sensitivity of the TOF instrument, further aggravated by matrix signal suppression, did not allow the acquisition of data for wine samples that contained less than 50 mug l(-1) in the direct sample introduction mode. The separation and preconcentration of lead were therefore required. The precision obtained for the Pb-206/Pb-207 and Pb-208/Pb-206 were similar and equal to 0.14-2.7% for Q ICP MS, 0.04-0.17% for TOF ICP MS and 0.01-0.12% for MC ICP MS. The precision for Pb-206/Pb-204 was 0.44-5.29, 0.15-1.7, 0.08-1.6%, respectively. On the level of accuracy, the data from TOF ICP MS and MC ICP MS were in good agreement. The accuracy of Q ICP MS data was judged satisfactory in comparison with the other techniques but their poor precision Ic as a significant obstacle on the way of using these data for the determination of the geographic origin of wine, (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:307 / 317
页数:11
相关论文
共 40 条
[21]  
LEGRAND V, 1991, ANALUSIS, V19, pM39
[22]   ORGANOLEAD COMPOUNDS IN ARCHIVES OF ENVIRONMENTAL-POLLUTION [J].
LOBINSKI, R .
ANALYST, 1995, 120 (03) :615-621
[23]  
LOBINSKI R, 1993, J AOAC INT, V76, P1262
[24]   ORGANOLEAD IN WINE [J].
LOBINSKI, R ;
WITTE, C ;
ADAMS, FC ;
TEISSEDRE, PL ;
CABANIS, JC ;
BOUTRON, CF .
NATURE, 1994, 370 (6484) :24-24
[25]   Flow injection sorbent extraction with dialkyldithiophosphates as chelating agent for the determination of cadmium, copper and lead by flame atomic absorption spectrometry [J].
Ma, RL ;
Adams, F .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1917-1923
[26]  
MCCURDY E, 1992, LAB NEWS, P10
[27]   Influence of atmospheric pollution on the lead content of wines [J].
Médina, B ;
Augagneur, S ;
Barbaste, M ;
Grouset, FE ;
Buat-Méard, P .
FOOD ADDITIVES AND CONTAMINANTS, 2000, 17 (06) :435-445
[28]   Assessment of the precision and accuracy of lead-isotope ratios measured by TIMS for geochemical applications: example of massive sulphide deposits (Rio Tinto, Spain) [J].
Pomies, C ;
Cocherie, A ;
Guerrot, C ;
Marcoux, E ;
Lancelot, J .
CHEMICAL GEOLOGY, 1998, 144 (1-2) :137-149
[29]   Accuracy and long-term reproducibility of lead isotopic measurements by multiple-collector inductively coupled plasma mass spectrometry using an external method for correction of mass discrimination [J].
Rehkämper, M ;
Halliday, AN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 181 :123-133
[30]   Lead concentrations and isotopic signatures in vintages of French wine between 1950 and 1991 [J].
Rosman, KJR ;
Chisholm, W ;
Jimi, S ;
Candelone, JP ;
Boutron, CF ;
Teissedre, PL ;
Adams, FC .
ENVIRONMENTAL RESEARCH, 1998, 78 (02) :161-167