Radiometric calibration for the airborne interferometric monitor for greenhouse gases simulator

被引:25
作者
Shimota, A [1 ]
Kobayashi, H [1 ]
Kadokura, S [1 ]
机构
[1] Cent Res Inst Elect Power Ind, Komae, Tokyo 201, Japan
关键词
D O I
10.1364/AO.38.000571
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The Advanced Earth Observation Satellite (ADEOS), launched in the summer of 1996, has a high-resolution infrared Fourier transform spectrometer, with the interferometric monitor for greenhouse gases (IMG) onboard. The IMG has a high spectral resolution of 0.1 cm(-1) for the purpose of retrieving greenhouse gas profile maps of the Earth. To meet the requirements of the retrieval algorithms for greenhouse gas profiles, atmospheric emission spectra must be calibrated to better than 1 K accuracy. Prior to the launch of the ADEOS with the IMG, we developed an airborne simulator called the tropospheric infrared interferometric sounder (TIIS). We explain the calibration procedure for the TIIS, which determines the points with the same optical path difference an interferograms for complex Fourier transformation, using the retained phase term on the calibrated spectrum. The downward atmospheric radiation, measured with the TIIS, was well calibrated using this algorithm. Furthermore, calibration of the spectra obtained from the IMG initial checkout mission observation was carried out. (C) 1999 Optical Society of America.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 8 条
  • [1] ANDERSON GP, 1992, FASCOD3P USER GUIDE
  • [2] GRIFFITHS PR, 1986, FOURIER TRANSFORM IN, P48
  • [3] KOBAYASHI H, 1993, T93077 CENTR RES I E
  • [4] KOBAYASHI H, 1991, T91018 CENTR RES I E
  • [5] NISHIZAWA S, 1994, 5 WORKSH ATM SCI SPA
  • [6] RADIOMETRIC CALIBRATION OF IR FOURIER-TRANSFORM SPECTROMETERS - SOLUTION TO A PROBLEM WITH THE HIGH-RESOLUTION INTERFEROMETER SOUNDER
    REVERCOMB, HE
    BUIJS, H
    HOWELL, HB
    LAPORTE, DD
    SMITH, WL
    SROMOVSKY, LA
    [J]. APPLIED OPTICS, 1988, 27 (15): : 3210 - 3218
  • [7] Effects of the self-emission of an IR Fourier-transform spectrometer on measured absorption spectra
    Schreiber, J
    Blumenstock, T
    Fischer, H
    [J]. APPLIED OPTICS, 1996, 35 (31): : 6203 - 6209
  • [8] PHASE CORRECTIONS FOR THE EMISSION SOUNDER MIPAS-FT
    WEDDIGEN, C
    BLOM, CE
    HOPFNER, M
    [J]. APPLIED OPTICS, 1993, 32 (24): : 4586 - 4589