摘要
Background: Scanning laser polarimetry is a tool for measuring the retinal nerve fiber layer: both its cross-sectional surface (polarimetric data analysis) and its thickness (mean sector values). Methods: Two observers examined 56 normal volunteers twice by means of scanning laser polarimetry (Nerve Fiber Analyzer type 1, software version 1.6). Measurements of the retinal nerve fiber layer were carried out in four equal sectors of a circle around the optic nerve head. The measured values of the sectors and the calculated ratios among them were used for statistical analysis. Interobserver and intraobserver reproducibility were analyzed following a balanced random three-way cross classification with interactions. Interobserver reproducibility was defined as the part of variance not influenced by the observers. Intraobserver reproducibility was defined as the part of variance not influenced by the time. Results: For repeated measurements of the retinal nerve fiber layer, better intraobserver than interobserver reproducibility was found (9.57-0.79 vs 0.11-0.43). The interobserver reproducibility was improved (0.24-0.65) in comparison to the intraobserver reproducibility (0.32-0.68) by calculating the ratios of the measured values. Conclusion: The instrument is clinically useful only if used by the same observer. If measurements are performed by different observers the ratios of the measurements must be used. Further development in the apparatus is needed to improve interobserver reproducibility.
引用
收藏
页码:628 / 632
页数:5
相关论文
共 16 条
[1]  
CAPRIOLI J, 1990, OPHTHALMOLOGY, V97, P358
[2]  
CAPRIOLI J, 1989, OPHTHALMOLOGY, V96, P633
[3]  
DREHER AW, 1992, CLIN VISION SCI, V7, P481
[4]  
EIKELBOOM RH, 1990, INVEST OPHTH VIS SCI, V31, P2373
[5]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[6]   SHORT-WAVELENGTH AUTOMATED PERIMETRY IN LOW-RISK, MEDIUM-RISK, AND HIGH-RISK OCULAR HYPERTENSIVE EYES - INITIAL BASE-LINE RESULTS [J].
JOHNSON, CA ;
BRANDT, JD ;
KHONG, AM ;
ADAMS, AJ .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (01) :70-76
[7]  
JONAS JB, 1989, OPHTHALMOLOGY, V96, P627
[8]  
PULIAFITO CA, 1995, OPHTHALMOLOGY, V102, P217
[9]  
QUIGLEY HA, 1982, ARCH OPHTHALMOL-CHIC, V100, P807
[10]   RETINAL GANGLION-CELL ATROPHY CORRELATED WITH AUTOMATED PERIMETRY IN HUMAN EYES WITH GLAUCOMA [J].
QUIGLEY, HA ;
DUNKELBERGER, GR ;
GREEN, WR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (05) :453-464