Interventional Pain Relief Using Balloon-Kyphoplasty in Patients with Osteoporotic-Based Fatigue Fractures of the Os Sacrum

被引:15
作者
Andresen, R. [1 ,2 ,3 ]
Radmer, S. [4 ]
Kamusella, P. [1 ,2 ,3 ]
Wissgott, C. [1 ,2 ,3 ]
Banzer, J. [5 ,6 ]
Schober, H. C. [7 ]
机构
[1] Univ Kiel, Akad Lehrkrankenhaus, W Kustenklinikum Heide, Inst Diagnost & Intervent Radiol Neuroradiol, D-25746 Heide, Germany
[2] Univ Lubeck, Akad Lehrkrankenhaus, W Kustenklinikum Heide, Inst Diagnost & Intervent Radiol Neuroradiol, D-25746 Heide, Germany
[3] Univ Hamburg, Akad Lehrkrankenhaus, W Kustenklinikum Heide, Inst Diagnost & Intervent Radiol Neuroradiol, D-25746 Heide, Germany
[4] Zentrum Bewegungsheilkunde, Berlin, Germany
[5] Charite Univ Med Berlin, Radiol Klin, Berlin, Germany
[6] Charite Univ Med Berlin, Hsch Ambulanz Radiol, Berlin, Germany
[7] Univ Rostock, Akad Lehrkrankenhaus, Klinikum Sudstadt Rostock, Innere Med Klin 1, D-2500 Rostock 1, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2012年 / 184卷 / 01期
关键词
fatigue fracture; os sacrum fracture; osteoporosis; balloon sacroplasty; interventional pain relief; INSUFFICIENCY FRACTURES; PERCUTANEOUS SACROPLASTY; FLUOROSCOPIC GUIDANCE; GUIDED SACROPLASTY; CT; CEMENTOPLASTY;
D O I
10.1055/s-0031-1281782
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: In older patients with reduced bone quality, fatigue fractures of the os sacrum are relatively common and are typically accompanied by strong, disabling pain. The aim of our study was to verify the feasibility and safety of sacroplasty using a balloon catheter as well as the reduction of pain. Materials and Methods: 25 patients were diagnosed with an os sacrum fracture in MRI. As a manifestation of an extant bone reconstruction process, all patients were diagnosed with distinctive edema on the basis of MRI strong T2-weighted images. CT-controlled balloon sacroplasty was performed in all patients. To allow the cement to be dispensed at a longitudinal angle to the fracture, the balloon catheter is directed through a hollow needle in the os sacrum either from the caudal to the cranial direction or from the craniodorsal to the caudoventral direction. The thus created cavity was then filled with PMMA cement. A control CT and a conventional X-ray in two planes were then carried out. The pain intensity was defined by means of VAS before the intervention, on the second day, and 6 and 12 months after the intervention. Results: The balloon sacroplasty yielded good technical performance in every patient. The control CT and the X-ray control of the os sacrum showed adequate distribution of the cement, and cement leakage was not detected. Before the operation, the average pain encountered was in accordance with VAS 8.3. On the second postoperative day, a considerable reduction with an average of 2.7 was reported, and this remained stable with an average of 2.5 after 6 and 12 months. Conclusion: Balloon sacroplasty is an effective treatment method for fast pain relief in patients with fatigue fractures of the os sacrum.
引用
收藏
页码:32 / 36
页数:5
相关论文
共 44 条
[1]
Mechanical analysis of percutaneous sacroplasty using CT image based finite element models [J].
Anderson, Dennis E. ;
Cotton, John R. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (03) :316-325
[2]
Andresen R, 1998, ACTA RADIOL, V39, P538
[3]
The controversy surrounding sacral insufficiency fractures - To ambulate or not to ambulate? [J].
Babayev, M ;
Lachmann, E ;
Nagler, W .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2000, 79 (04) :404-409
[4]
Clinical outcomes of sacroplasty in sacral insufficiency fractures: a review of the literature [J].
Bayley, Edward ;
Srinivas, Shreya ;
Boszczyk, Bronek M. .
EUROPEAN SPINE JOURNAL, 2009, 18 (09) :1266-1271
[5]
Betts A, 2008, PAIN PHYSICIAN, V11, P57
[6]
A new, easy, fast, and safe method for CT-guided sacroplasty [J].
Binaghi, Stefano ;
Guntern, Daniel ;
Schnyder, Pierre ;
Theumann, Nicolas .
EUROPEAN RADIOLOGY, 2006, 16 (12) :2875-2878
[7]
Briem D, 2008, UNFALLCHIRURG, V111, P381, DOI 10.1007/s00113-008-1432-x
[8]
Computerized tomography guided sacroplasty: A practical treatment for sacral insufficiency fracture - Case report [J].
Brook, AL ;
Mirsky, DM ;
Bello, JA .
SPINE, 2005, 30 (15) :E450-E454
[9]
Percutaneous sacroplasty for the treatment of sacral insufficiency fractures [J].
Butler, CL ;
Given, CA ;
Michel, SJ ;
Tibbs, PA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1956-1959
[10]
MRI and CT of Insufficiency Fractures of the Pelvis and the Proximal Femur [J].
Cabarrus, Miguel C. ;
Ambekar, Avanti ;
Lu, Ying ;
Link, Thomas M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) :995-1001