Simultaneous determination of common mono- and divalent cations by ion chromatography with an unmodified silica gel column

被引:28
作者
Ohta, K [1 ]
Sando, M [1 ]
Tanaka, K [1 ]
Haddad, PR [1 ]
机构
[1] UNIV TASMANIA,DEPT CHEM,HOBART,TAS 7001,AUSTRALIA
关键词
water analysis; silica gel; cations;
D O I
10.1016/S0021-9673(96)00475-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In order to characterize the cation-exchange properties of a silica gel column in the acidic region, the retention behavior of common mono- and divalent cations (Na+, NH4+, K+, Mg2+ and Ca2+) was investigated. When using 5 mM nitric acid (pH 2.3) as an eluent, these cations were retained on a silica gel column (150x4.6 mm I.D.) packed with Develosil 30-5 unmodified silica gel that has a very large surface area (ca. 770 m(2)/g), showing that such a stationary phase could be used as a cation-exchanger for ion chromatography with acidic eluents. When using 1.5 mM nitric acid and 0.5 mM 2,6-pyridinedicarboxylic acid as an eluent, a good separation of these cations was obtained in 12 min using conductimetric detection. This separation was applied successfully to the simultaneous determination of the five cations in various environmental water samples.
引用
收藏
页码:167 / 172
页数:6
相关论文
共 11 条
[1]  
[Anonymous], 1964, STABILITY CONSTANTS
[2]   ANION-CATION SEPARATIONS ON A MIXED BED ALUMINA-SILICA COLUMN [J].
BROWN, DM ;
PIETRZYK, DJ .
JOURNAL OF CHROMATOGRAPHY, 1989, 466 :291-300
[3]   CATION CHROMATOGRAPHY WITH A CONDUCTIVITY DETECTOR [J].
FRITZ, JS ;
GJERDE, DT ;
BECKER, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (09) :1519-1522
[4]   SIMULTANEOUS DETERMINATION OF SODIUM AND POTASSIUM-IONS IN RIVER WATER BY ION CHROMATOGRAPHY USING SILICA-GELS AS A STATIONARY PHASE [J].
IWACHIDO, T ;
ISHIMARU, K ;
MOTOMIZU, S .
ANALYTICAL SCIENCES, 1988, 4 (01) :81-85
[5]   ION CHROMATOGRAPHIC DETERMINATION OF SODIUM, POTASSIUM, MAGNESIUM AND CALCIUM-IONS IN RIVER WATER [J].
IWACHIDO, T ;
SHINOMIYA, M ;
ZENKI, M .
ANALYTICAL SCIENCES, 1990, 6 (02) :277-282
[6]   DETERMINATION OF AMMONIUM AND OTHER MAJOR CATIONS IN RIVER AND RAIN WATER BY ION CHROMATOGRAPHY USING SILICA-GEL AS AN ION-EXCHANGER [J].
IWACHIDO, T ;
IKEDA, T ;
ZENKI, M .
ANALYTICAL SCIENCES, 1990, 6 (04) :593-597
[7]  
KOLLA P, 1988, FRESEN Z ANAL CHEM, V332, P333
[8]  
Scott R.P. W., 1993, SILICA GEL BONDED PH
[9]   LIQUID-CHROMATOGRAPHIC SEPARATION OF METAL-IONS ON A SILICA COLUMN [J].
SMITH, RL ;
PIETRZYK, DJ .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :610-614
[10]   DETERMINATION OF THE SPECIFIC SURFACE-AREA OF SILICA-GEL BY ON-COLUMN TITRATION WITH HYDROCHLORIC-ACID [J].
TAKEUCHI, T ;
MIWA, T .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :565-570