External fixation in comminuted, displaced intra-articular fractures of the distal radius: is it sufficient?

被引:23
作者
Arora, J
Malik, AC
机构
[1] N Tyneside Gen Hosp, Newcastle Upon Tyne NE6 5TY, Tyne & Wear, England
[2] Safdarjang Hosp, Cent Inst Orthopaed, New Delhi 110088, India
关键词
intra-articular fractures; distal radius; external fixation;
D O I
10.1007/s00402-005-0033-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: External fixation has been extensively used to treat the intra-articular fractures of the distal radius and it has several distinct advantages over conventional POP cast and plate fixation. However, the limitation of external fixation to achieve articular congruity in the comminuted intra-articular fractures of the distal radius has been documented in the literature. This could be because external fixation alone does not expand crushed cancellous bone and cannot work without soft tissue hinges. This prospective study was conducted to look at the results of comminuted, displaced intra-articular fractures of the distal radius treated exclusively by external fixation. Materials and methods: A 2-year follow-up of 27 patients with comminuted, displaced intra-articular fractures of distal radius that were treated exclusively by external fixation is presented. The radiological results, functional results and complications were analyzed according to the scoring system given by Jakim et al. Results: Anatomical reduction could not be achieved in 12 patients (44%) and reduction was lost in two patients (7%). Excellent and good results were seen in 59.3%, fair results were seen in 22.2% and poor results were seen in 18.5% of the cases. Outcome scores of patients without articular step were significantly better as compared to the patients with articular step at healing. There was a positive correlation between the restoration of normal anatomy (radiological results) and the functional outcome (r=0.775). Overall nine patients (33%) had complications. Conclusion: We conclude that although the external fixation is reliable in maintaining the reduction in displaced comminuted intra-articular fractures, it is inadequate in restoring articular congruity in many cases. The complications of external fixation are frequent and may be potentially serious in nature.
引用
收藏
页码:536 / 540
页数:5
相关论文
共 19 条
[1]
AGEE JM, 1995, HAND CLIN, V4, P577
[2]
ALTISSIMI M, 1986, CLIN ORTHOP RELAT R, P202
[3]
The application of indirect reduction techniques in the distal radius:: The role of adjuvant arthroscopy [J].
Auge, WK ;
Velázquez, PA .
ARTHROSCOPY, 2000, 16 (08) :830-835
[4]
INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS - A CADAVERIC STUDY TO DETERMINE IF LIGAMENTOTAXIS RESTORES RADIOPALMAR TILT [J].
BARTOSH, RA ;
SALDANA, MJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :18-21
[5]
Cole RJ, 1997, J HAND SURG-AM, V22A, P792
[6]
HANU T, 1991, J HAND SURG A, V16, P392
[7]
HORESH Z, 1991, CLIN ORTHOP RELAT R, P147
[8]
Hugh SD, 1985, INJURY, V16, P289
[9]
EXTERNAL FIXATION FOR INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
JAKIM, I ;
PIETERSE, HS ;
SWEET, MBE .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :302-306
[10]
Displaced intra-articular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation [J].
Kapoor, H ;
Agarwal, A ;
Dhaon, BK .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (02) :75-79