Dural tissue trauma and cerebrospinal fluid leak after epidural needle puncture - Effect of needle design, angle, and bevel orientation

被引:22
作者
Angle, PJ [1 ]
Kronberg, JE [1 ]
Thompson, DE [1 ]
Ackerley, C [1 ]
Szalai, JP [1 ]
Duffin, J [1 ]
Faure, P [1 ]
机构
[1] Univ Toronto, Sunnybrook & Womens Coll Hlth Sci Ctr, Toronto, ON M5S 1B2, Canada
关键词
D O I
10.1097/00000542-200312000-00021
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The effects of epidural needle design, angle, and bevel orientation on cerebrospinal fluid leak after puncture have not been reported. The impact of these factors on leak rate was examined using a dural sac model. Dural trauma was examined using scanning electron microscopy. Methods: Human cadaveric dura, mounted on a cylindrical model, was punctured with epidural needles using a micromanipulator. Tissue was punctured at 15 cm H2O (left lateral decubitus) system pressure, and leak was measured at 25 cm H2O (semisitting) pressure. Leak rates and trauma were compared for the following: (1) six different epidural needles at 90degrees, bevel parallel to the dural long axis; (2) 18-gauge Tuohy and 18-gauge Special Sprotte(R) epidural needles, 30degrees versus 90degrees; (3) 18-gauge Tuohy, bevel perpendicular versus parallel to the dural long axis. Results: With the 90degrees puncture, bevel parallel, the greatest leak occurred with a 17-gauge Hustead (516 +/- 319 ml/15 min), and the smallest leak occurred with a 20-gauge Tuohy (100 +/- 112 ml/15 min; P = 0.0018). A 20-gauge Tuohy puncture led to statistically significant reductions in leak (P value range, 0.0001-0.0024) compared with all needles except the Special Sprotte(R). With the 30degrees versus 90degrees angle, 30degrees punctures with an 18-gauge Tuohy produced nonstatistically significant leak reductions compared with the 18-gauge Tuohy at 90degrees. The puncture angle made no difference for the Special Sprotte(R). Nonsignificant reductions were found for the Special Sprotte(R) compared with the Tuohy. With the 18-gauge Tuohy bevel orientation, perpendicular orientation produced nonstatistically significant reductions in leak compared with parallel orientation. Conclusions: Cerebrospinal fluid leak after puncture was influenced most by epidural needle gauge. Leak rate was significantly less for the 20-gaugc Tuohy needle.
引用
收藏
页码:1376 / 1382
页数:7
相关论文
共 21 条
[1]   Headache after attempted epidural block - The role of intrathecal air [J].
Aida, S ;
Taga, K ;
Yamakura, T ;
Endoh, H ;
Shimoji, K .
ANESTHESIOLOGY, 1998, 88 (01) :76-81
[2]   Post-spinal headache after dural puncture with perpendicular or horizontal needle bevel direction:: a randomized controlled trial in an African rural hospital [J].
Ansaloni, L ;
Balzani, C ;
Falaschi, F ;
Pazè, E .
TROPICAL DOCTOR, 2000, 30 (03) :167-169
[3]   An audit of epidural blood patch after accidental dural puncture with a Tuohy needle in obstetric patients [J].
Banks, S ;
Paech, M ;
Gurrin, L .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2001, 10 (03) :172-176
[4]   North American survey of the management of dural puncture occurring during labour epidural analgesia [J].
Berger, CW ;
Crosby, ET ;
Grodecki, W .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (02) :110-114
[5]   FLUID-FLOW THROUGH DURAL PUNCTURE SITES - AN INVITRO COMPARISON OF NEEDLE POINT TYPES [J].
CRUICKSHANK, RH ;
HOPKINSON, JM .
ANAESTHESIA, 1989, 44 (05) :415-418
[6]   ANATOMICAL RE-EVALUATION OF LUMBAR DURA MATER WITH REGARD TO POSTSPINAL HEADACHE - EFFECT OF DURAL PUNCTURE [J].
DITTMANN, M ;
SCHAFER, HG ;
ULRICH, J ;
BONDTAYLOR, W .
ANAESTHESIA, 1988, 43 (08) :635-637
[7]  
FAY T, 1940, DIS NERVOUS SYS 1008, P312
[8]   POSTDURAL PUNCTURE HEADACHE AND SPINAL NEEDLE DESIGN [J].
HALPERN, S ;
PRESTON, R .
ANESTHESIOLOGY, 1994, 81 (06) :1376-1383
[9]  
HATFALVI BI, 1995, REGION ANESTH, V20, P329
[10]  
Holst D, 1998, ANESTH ANALG, V87, P1331