Increased accuracy of echocardiographic measurement of flow using automated spherical integration of multiple plane velocity vectors

被引:8
作者
Brandberg, J
Janerot-Sjöberg, B
Ask, P
机构
[1] Linkoping Univ, Dept Biomed Engn, Linkoping, Sweden
[2] Linkoping Univ, Dept Clin Physiol, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
SIVV; Doppler ultrasound; blood flow; cardiac output;
D O I
10.1016/S0301-5629(98)00159-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The calculation of blood flow in the heart by surface integration of velocity vectors (SIVV) using Doppler ultrasound is independent of the angle. Flow is normally calculated from velocity in a spherical thick shell with its center located at the ultrasound transducer. In a numerical simulation, we have shown that the ratio between minor and major axes of an elliptic flow area substantially influences the accuracy of the estimation of flow in a single scan plane. The accuracy of how measurements by SIVV can be improved by calculating the mean of the values from more than one scan plane. We have produced an automated computer program that includes an antialiasing procedure. We confirmed an improvement of flow measurements in a pulsatile hydraulic flow model, the 95% confidence interval for single estimations being reduced from 20% to 10% (p < 0.05) using the newly developed software. We think that the SIVV method has important implications for clinical transthoracic echocardiography, (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 17 条
[1]   CLINICAL-ASSESSMENT OF CARDIAC-OUTPUT [J].
CONWAY, J .
EUROPEAN HEART JOURNAL, 1990, 11 :148-150
[2]   SOME COMMENTS ON THE USEFULNESS OF MEASURING CARDIAC-OUTPUT BY DYE DILUTION [J].
DELEEUW, PW ;
BIRKENHAGER, WH .
EUROPEAN HEART JOURNAL, 1990, 11 :13-16
[3]   REGURGITANT HEART-VALVE FLOW FROM 2-D PROXIMAL VELOCITY-FIELD - CONTINUED SEARCH FOR THE IDEAL METHOD [J].
EIDENVALL, L ;
BARCLAY, S ;
LOYD, D ;
WRANNEL, B ;
ASK, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (02) :131-139
[4]  
Eidenvall L, 1992, J Am Soc Echocardiogr, V5, P405
[5]  
FAGARD R, 1990, EUR HEART J, V11, P1
[6]  
FYRENIUS A, 1997, ECHOCARDIOGR-J CARD, V14, pS61
[7]  
IHLEN H, 1984, BRIT HEART J, V51, P54
[8]   A new Doppler method for quantification of volumetric flow: In vivo validation using color Doppler [J].
Kim, WY ;
Poulsen, JK ;
Terp, K ;
Staalsen, NH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (01) :182-192
[10]  
POULSEN JK, 1996, IEEE T BIOMED ENG, V43, P1