Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia

被引:26
作者
Crump, JA
Tanner, DC
Mirrett, S
McKnight, CM
Reller, LB
机构
[1] Duke Univ, Med Ctr, Clin Microbiol Lab, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Pathol, Durham, NC 27710 USA
[3] Duke Univ, Sch Med, Dept Med, Durham, NC 27710 USA
[4] Carolinas Med Ctr, Clin Microbiol Lab, Charlotte, NC 28203 USA
关键词
D O I
10.1128/JCM.41.5.1987-1990.2003
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMerieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube required for each system. Of 600 sets tested, 85 (14%) yielded Mycobacterium avium complex (MAC) and 9 (2%) yielded other species of mycobacteria. Of 26 complete (three bottles and one tube) adequately filled (5 +/- 1 ml) sets from which MAC was recovered, BACTEC 13A was positive for 19 (73%), BACTEC MYCO/F LYTIC was positive for 21 (81%), BacT/ALERT MB was positive for 22 (85%), and ISOLATOR 10 was positive for 21 (81%). Of the six possible two-way comparisons, the mean times to detection for the recovery of MAC from each bottle in positive adequately paired sets were 15.3 days for BACTEC 13A versus 12.8 days for MYCO/F LYTIC for 33 of 340 pairs, 14.1 days for BACTEC 13A versus 11.6 days for BacT/ALERT MB for 38 of 380 pairs, 12.6 days for BACTEC 13A versus 20.0 days for ISOLATOR 10 for 26 of 261 pairs, 12.8 days for BACTEC MYCO/F LYTIC versus 11.0 days for BacT/ALERT MB for 33 of 340 pairs, 13.2 days for BACTEC MYCO/F LYTIC versus 20.4 days for ISOLATOR 10 for 24 of 230 pairs, and 9.9 days for BacT/ALERT MB versus 19.0 days for ISOLATOR 10 for 24 of 257 pairs. There were no significant differences in yields between the systems. However, the mean time to detection differed significantly among the systems. The time to detection was shortest for BacT/ALERT NIB, followed by BACTEC MYCO/F LYTIC and BACTEC 13A and then ISOLATOR 10. Although the numbers were too small for statistical comparison, the time to detection was substantially shorter for MAC than for Mycobacterium tuberculosis complex in the liquid systems. The continuously monitored systems (BACTEC MYCQ/F LYTIC and BacT/ALERT MB) were as sensitive and, on balance, faster for the detection of MAC bacteremia than were the heretofore standard manual ISOLATOR 10 and radiometric BACTEC 13A systems.
引用
收藏
页码:1987 / 1990
页数:4
相关论文
共 18 条
  • [1] Fever and human immunodeficiency virus infection as sentinels for emerging mycobacterial and fungal bloodstream infections in hospitalized patients ≥15 years old, Bangkok
    Archibald, LK
    McDonald, LC
    Rheanpumikankit, S
    Tansuphaswadikul, S
    Chaovanich, A
    Eampokalap, B
    Banerjee, SN
    Reller, LB
    Jarvis, WR
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1999, 180 (01) : 87 - 92
  • [2] Fatal Mycobacterium tuberculosis bloodstream infections in febrile hospitalized adults in Dar es Salaam, Tanzania
    Archibald, LK
    den Dulk, MO
    Pallangyo, KJ
    Reller, LB
    [J]. CLINICAL INFECTIOUS DISEASES, 1998, 26 (02) : 290 - 296
  • [3] Impact of highly active antiretroviral therapy on onset of Mycobacterium avium complex infection and cytomegalovirus disease in patients with AIDS
    Baril, L
    Jouan, M
    Agher, R
    Cambau, E
    Caumes, E
    Bricaire, F
    Katlama, C
    [J]. AIDS, 2000, 14 (16) : 2593 - 2596
  • [4] THE IMPACT OF MYCOBACTERIUM-AVIUM COMPLEX BACTEREMIA AND ITS TREATMENT ON SURVIVAL OF AIDS PATIENTS - A PROSPECTIVE-STUDY
    CHIN, DP
    REINGOLD, AL
    STONE, EN
    VITTINGHOFF, E
    HORSBURGH, CR
    SIMON, EM
    YAJKO, DM
    HADLEY, WK
    OSTROFF, SM
    HOPEWELL, PC
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1994, 170 (03) : 578 - 584
  • [5] Evaluation of BACTEC MYCO/F lytic medium for recovery of mycobacteria, fungi, and bacteria from blood
    Fuller, DD
    Davis, TE
    Denys, GA
    York, MK
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (08) : 2933 - 2936
  • [6] USE OF LYSIS-CENTRIFUGATION (ISOLATOR) AND RADIOMETRIC (BACTEC) BLOOD CULTURE SYSTEMS FOR THE DETECTION OF MYCOBACTEREMIA
    GILL, VJ
    PARK, CH
    STOCK, F
    GOSEY, LL
    WITEBSKY, FG
    MASUR, H
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (04) : 543 - 546
  • [7] Early manifestations of disseminated Mycobacterium avium complex disease: A prospective evaluation
    Gordin, FM
    Cohn, DL
    Sullam, PM
    Schoenfelder, JR
    Wynne, BA
    Horsburgh, CR
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1997, 176 (01) : 126 - 132
  • [8] EFFECT OF AGITATION OF BACTEC 13A BLOOD CULTURES ON RECOVERY OF MYCOBACTERIUM-AVIUM COMPLEX
    JACKSON, K
    SIEVERS, A
    DWYER, B
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (09) : 1801 - 1803
  • [9] Unrecognised Mycobacterium tuberculosis bacteraemia among hospital inpatients in less developed countries
    McDonald, LC
    Archibald, LK
    Rheanpumikankit, S
    Tansuphaswadikul, S
    Eampokalap, B
    Nwanyanawu, O
    Kazembe, P
    Dobbie, H
    Reller, LB
    Jarvis, WR
    [J]. LANCET, 1999, 354 (9185) : 1159 - 1163
  • [10] MCNEMAR Q, 1962, PSYCHOL STAT