Microfabricated disposable DNA sensor for detection of hepatitis B virus DNA

被引:76
作者
Hashimoto, K [1 ]
Ito, K [1 ]
Ishimori, Y [1 ]
机构
[1] Toshiba Corp, Ctr Res & Dev, Environm Engn Lab, Saiwai Ku, Kawasaki, Kanagawa 210, Japan
关键词
DNA sensor; photolithography; disposable; oligonucleotide; Hoechst; 33258; hepatitis B virus;
D O I
10.1016/S0925-4005(98)00121-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors report here a preliminary evaluation of a microfabricated disposable-type DNA sensor, based on photolithography technique, for the detection of hepatitis B virus (HBV) genome DNA. The DNA sensor was reacted with the HBV-DNA-inserted plasmid (pYRB259), immersed in a 100 mu mol/l Hoechst 33258 solution and washed with a phosphate buffer. The electrochemical analysis showed that the anodic peak current derived from Hoechst 33258 bound to the formed hybrids on the electrode was increased with increasing the concentration of pYRB259 in the range from 10(4) to 10(6) copy/ml. Then, the authors evaluated the concentration of HBV-DNA extracted from patients' sera using a DNA sensor and competitive polymerase chain reaction (C-PCR). A correlation coefficient of 0.89 was obtained between the two assay methods. The variance for each sample in triplicate measurements ranged from 2 to 6% in the inter-assay using the DNA. sensor. These results suggest that the microfabricated disposable DNA sensor can provide a specific and quantitative detection of HBV-DNA in sera. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 21 条
  • [1] Ausbel F. M., 1987, CURRENT PROTOCOLS MO
  • [2] LACTOSE REPRESSOR-OPERATOR DNA INTERACTIONS - KINETIC-ANALYSIS BY A SURFACE-PLASMON RESONANCE BIOSENSOR
    BONDESON, K
    FROSTELLKARLSSON, A
    FAGERSTAM, L
    MAGNUSSON, G
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 214 (01) : 245 - 251
  • [3] NOVEL DNA SENSOR FOR ELECTROCHEMICAL GENE DETECTION
    HASHIMOTO, K
    ITO, K
    ISHIMORI, Y
    [J]. ANALYTICA CHIMICA ACTA, 1994, 286 (02) : 219 - 224
  • [4] SEQUENCE-SPECIFIC GENE DETECTION WITH A GOLD ELECTRODE MODIFIED WITH DNA PROBES AND AN ELECTROCHEMICALLY ACTIVE DYE
    HASHIMOTO, K
    ITO, K
    ISHIMORI, Y
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (21) : 3830 - 3833
  • [5] Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance
    Ito, K
    Hashimoto, K
    Ishimori, Y
    [J]. ANALYTICA CHIMICA ACTA, 1996, 327 (01) : 29 - 35
  • [6] Voltammetric determination of sequence-specific DNA by electroactive intercalator on graphite electrode
    Liu, SH
    Ye, JN
    He, PG
    Fang, YH
    [J]. ANALYTICA CHIMICA ACTA, 1996, 335 (03) : 239 - 243
  • [7] MEYERHANS A, 1989, CELL, V320, P1458
  • [8] Mikkelsen Susan R., 1996, Electroanalysis, V8, P15, DOI 10.1002/elan.1140080104
  • [9] VOLTAMMETRIC DNA BIOSENSOR FOR CYSTIC-FIBROSIS BASED ON A MODIFIED CARBON-PASTE ELECTRODE
    MILLAN, KM
    SARAULLO, A
    MIKKELSEN, SR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (18) : 2943 - 2948
  • [10] HYBRIDIZATION OF NUCLEIC-ACIDS IMMOBILIZED ON A QUARTZ CRYSTAL MICROBALANCE
    OKAHATA, Y
    MATSUNOBU, Y
    IJIRO, K
    MUKAE, M
    MURAKAMI, A
    MAKINO, K
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (21) : 8299 - 8300