Protein electrochemistry using aligned carbon nanotube arrays

被引:717
作者
Gooding, JJ [1 ]
Wibowo, R
Liu, JQ
Yang, WR
Losic, D
Orbons, S
Mearns, FJ
Shapter, JG
Hibbert, DB
机构
[1] Univ New S Wales, Sch Chem Sci, Sydney, NSW 2052, Australia
[2] Flinders Univ S Australia, Sch Chem Phys & Earth Sci, Adelaide, SA 5001, Australia
关键词
D O I
10.1021/ja035722f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The remarkable electrocatalytic properties and small size of carbon nanotubes make them ideal for achieving direct electron transfer to proteins, important in understanding their redox properties and in the development of biosensors. Here, we report shortened SWNTs can be aligned normal to an electrode by self-assembly and act as molecular wires to allow electrical communication between the underlying electrode and redox proteins covalently attached to the ends of the SWNTs, in this case, microperoxidase MP-11. The efficiency of the electron transfer through the SWNTs is demonstrated by electrodes modified with tubes cut to different lengths having the same electron-transfer rate constant. Copyright © 2003 American Chemical Society.
引用
收藏
页码:9006 / 9007
页数:2
相关论文
共 22 条
  • [1] Bioelectrochemical single-walled carbon nanotubes
    Azamian, BR
    Davis, JJ
    Coleman, KS
    Bagshaw, CB
    Green, MLH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) : 12664 - 12665
  • [2] Balavoine F, 1999, ANGEW CHEM INT EDIT, V38, P1912, DOI 10.1002/(SICI)1521-3773(19990712)38:13/14<1912::AID-ANIE1912>3.0.CO
  • [3] 2-2
  • [4] Carbon nanotube electrode for oxidation of dopamine
    Britto, PJ
    Santhanam, KSV
    Ajayan, PM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01): : 121 - 125
  • [5] Electrochemistry using single carbon nanotubes
    Campbell, JK
    Sun, L
    Crooks, RM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (15) : 3779 - 3780
  • [6] Protein electrochemistry at carbon nanotube electrodes
    Davis, JJ
    Coles, RJ
    Hill, HAO
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2): : 279 - 282
  • [7] Parameters important in tuning the response of monolayer enzyme electrodes fabricated using self-assembled monolayers of alkanethiols
    Gooding, JJ
    Erokhin, P
    Hibbert, DB
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) : 229 - 239
  • [8] Parameters important in fabricating enzyme electrodes using self-assembled monolayers of alkanethiols
    Gooding, JJ
    Erokhin, P
    Losic, D
    Yang, WR
    Policarpio, V
    Liu, JQ
    Ho, FM
    Situmorang, M
    Hibbert, DB
    Shapter, JG
    [J]. ANALYTICAL SCIENCES, 2001, 17 (01) : 3 - 9
  • [9] Direct electron transfer of glucose oxidase on carbon nanotubes
    Guiseppi-Elie, A
    Lei, CH
    Baughman, RH
    [J]. NANOTECHNOLOGY, 2002, 13 (05) : 559 - 564
  • [10] GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS
    LAVIRON, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) : 19 - 28