Muscle artifact removal from human sleep EEG by using independent component analysis

被引:93
作者
Crespo-Garcia, Maite [1 ]
Atienza, Mercedes [1 ]
Cantero, Jose L. [1 ]
机构
[1] Univ Pablo Olavide, Lab Funct Neurosci, Ctra Utrera,Km 1, Seville 41013, Spain
关键词
muscle artifacts; sleep; arousals; awakenings; EEG; independent component analysis; blind source separation techniques;
D O I
10.1007/s10439-008-9442-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Muscle artifacts are typically associated with sleep arousals and awakenings in normal and pathological sleep, contaminating EEG recordings and distorting quantitative EEG results. Most EEG correction techniques focus on ocular artifacts but little research has been done on removing muscle activity from sleep EEG recordings. The present study was aimed at assessing the performance of four independent component analysis (ICA) algorithms (AMUSE, SOBI, Infomax, and JADE) to separate myogenic activity from EEG during sleep, in order to determine the optimal method. AMUSE, Infomax, and SOBI performed significantly better than JADE at eliminating muscle artifacts over temporal regions, but AMUSE was independent of the signal-to-noise ratio over non-temporal regions and markedly faster than the remaining algorithms. AMUSE was further successful at separating muscle artifacts from spontaneous EEG arousals when applied on a real case during different sleep stages. The low computational cost of AMUSE, and its excellent performance with EEG arousals from different sleep stages supports this ICA algorithm as a valid choice to minimize the influence of muscle artifacts on human sleep EEG recordings.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 59 条
[1]  
[Anonymous], 1986, Handbook of EEG and Clinical Neurophysiological Signals
[2]   AN INFORMATION MAXIMIZATION APPROACH TO BLIND SEPARATION AND BLIND DECONVOLUTION [J].
BELL, AJ ;
SEJNOWSKI, TJ .
NEURAL COMPUTATION, 1995, 7 (06) :1129-1159
[3]   A blind source separation technique using second-order statistics [J].
Belouchrani, A ;
AbedMeraim, K ;
Cardoso, JF ;
Moulines, E .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1997, 45 (02) :434-444
[4]   Robust whitening procedure in blind source separation context [J].
Belouchrani, A ;
Cichocki, A .
ELECTRONICS LETTERS, 2000, 36 (24) :2050-2051
[5]  
BERG P, 2000, CLIN PHYSL, V12, P49
[6]  
BONNET MH, 1992, SLEEP, V15, P526
[7]  
Bonnet MH, 2007, J CLIN SLEEP MED, V3, P271
[8]  
Boselli M, 1998, SLEEP, V21, P351
[9]  
Boudet Samuel, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P5719
[10]   Muscle artifacts in the sleep EEG: Automated detection and effect on all-night EEG power spectra [J].
Brunner, DP ;
Vasko, RC ;
Detka, CS ;
Monahan, JP ;
Reynolds, CF ;
Kupfer, DJ .
JOURNAL OF SLEEP RESEARCH, 1996, 5 (03) :155-164