Improvement in endocardial border delineation using tissue harmonic imaging

被引:57
作者
Becher, H [1 ]
Tiemann, K [1 ]
Schlosser, T [1 ]
Pohl, C [1 ]
Nanda, NC [1 ]
Averkiou, MA [1 ]
Powers, J [1 ]
Lüderitz, B [1 ]
机构
[1] Univ Bonn, Dept Cardiol, D-53105 Bonn, Germany
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 1998年 / 15卷 / 05期
关键词
tissue harmonic imaging; left ventricular endocardial border delineation; clutter; artifacts;
D O I
10.1111/j.1540-8175.1998.tb00642.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Methods: For years, tissue has been, assumed to be a linear medium in diagnostic ultrasound applications; thus, no backscattered signals in the second harmonic band are expected in, harmonic imaging without the injection of a contrast agent. However, it has been shown, that a useful tissue image is formed even without a contrast agent. The aim of this study teas to evaluate whether this tissue harmonic image provided improved visualization of endocardial borders. Fifty-six adult patients with various heart diseases were investigated using conventional two-dimensional echocardiography and tissue harmonic imaging. In 30 of these patients, the left ventricular endocardial borders were well defined in, the standard parasternal and apical views using conventional two-dimensional echocardiography. In the remaining 26 patients, delineation of endocardial borders was not possible in, at least two segments. The equipment used was an ATL HDI-3000 diagnostic system equipped with harmonic imaging. Results: In all 56 patients, the myocardium and valves could be imaged with tissue harmonic imaging. Harmonic recordings were sharper and contained fewer clutter artifacts than conventional recordings. Most striking was the enhancement of left ventricular endocardial borders. In the 26 patients with incomplete delineation of left ventricular endocardial borders, wall motion could be evaluated in 290 of 312 (93%) segments with tissue harmonic imaging compared with only 168 of 312 (54%) segments with conventional echocardiography (P < 0.001). Conclusions: Tissue harmonic imaging improves image quality and can be used to enhance the definition of left ventricular endocardial borders. These findings can be explained by the nonlinear propagation of ultrasound within the tissue, which results in distortion of the transmitted signal and, thus, harmonic generation.
引用
收藏
页码:511 / 517
页数:7
相关论文
共 12 条
[1]   Nonlinear distortion of short pulses radiated by plane and focused circular pistons [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05) :2539-2548
[2]   Measurements of harmonic generation in a focused finite-amplitude sound beam [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (06) :3439-3442
[3]  
AVERKIOU MA, 1997, IEEE ULTR S TOR CAN
[4]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[5]   Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :125-139
[6]   PRINCIPLES AND RECENT DEVELOPMENTS IN ULTRASOUND CONTRAST AGENTS [J].
DEJONG, N ;
TENCATE, FJ ;
LANCEE, CT ;
ROELANDT, JRTC ;
BOM, N .
ULTRASONICS, 1991, 29 (04) :324-330
[7]   ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
ERBEL, R ;
SCHWEIZER, P ;
LAMBERTZ, H ;
HENN, G ;
MEYER, J ;
KREBS, W ;
EFFERT, S .
CIRCULATION, 1983, 67 (01) :205-215
[8]  
Evans D. H., 1989, DOPPLER ULTRASOUND P
[9]   INTRAVENOUS ALBUNEX DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY - ENHANCED LOCALIZATION OF LEFT-VENTRICULAR ENDOCARDIAL BORDERS [J].
FALCONE, RA ;
MARCOVITZ, PA ;
PEREZ, JE ;
DITTRICH, HC ;
HOPKINS, WE ;
ARMSTRONG, WF .
AMERICAN HEART JOURNAL, 1995, 130 (02) :254-258
[10]  
PYLES JM, 1997, CIRCULATION S1, V96, P585