Improving accessibility of the impedance-based structural health monitoring method

被引:224
作者
Peairs, DM [1 ]
Park, G [1 ]
Inman, DJ [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Ctr Intelligent Mat Syst & Struct, Blacksburg, VA 24061 USA
关键词
impedance method; pipeline; composite structures; bolted joint; inexpensive; monitoring;
D O I
10.1177/1045389X04039914
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents current research on impedance-based structural health monitoring technique. The basic principle behind this technique is to apply high-frequency structural excitations (typically higher than 30 kHz) through the surface-bonded piezoelectric transducers, and measure the impedance of structures by monitoring the current and voltage applied to the piezoelectric transducers. Changes in impedance indicate changes in the structure, which in turn can indicate that damage has occurred. Three examples, including a bolted joint, gas pipeline, and composite structure, are presented to illustrate the effectiveness of this health monitoring technique to a wide variety of practical field applications. Although many proof-of-concept experiments have been performed using the impedance methods, the impedance-measuring device (HP4194A) is still bulky and expensive. Therefore, an operational amplifier-based turnkey device that can measure and record the electric impedance of a PZT has been developed. The performance of this miniaturized and portable device has been compared to our previous results and its effectiveness has been demonstrated.. This paper summarizes the experimental setup, procedures, and considerations needed to implement the device in field applications.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 12 条
[1]  
Eidinger J.M., 1999, P 5 US C LIF EARTHQ, P100
[2]  
Giurgiutiu V, 1997, STRUCTURAL HEALT H MONITORING, P433
[3]  
Koseki J., 1998, SOILS FOUND, V38, P75, DOI [10.3208/sandf.38.3_75, DOI 10.3208/SANDF.38.3_75]
[4]  
LIANG C, 1994, J INTEL MAT SYST STR, V5, P12, DOI [10.1177/1045389X9400500102, 10.1177/1045389X9700800406]
[5]  
Lopes V, 2000, J INTEL MAT SYST STR, V11, P206, DOI 10.1106/HOEV-7PWM-QYHW-E7VF
[6]  
O'Rourke TD, 1996, EARTHQ SPECTRA, V20, P493
[7]  
Park G, 2000, J INTEL MAT SYST STR, V11, P448, DOI 10.1106/QXMV-R3GC-VXXG-W3AQ
[8]   Impedance-based structural health monitoring for temperature varying applications [J].
Park, G ;
Kabeya, K ;
Cudney, HH ;
Inman, DJ .
JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING, 1999, 42 (02) :249-258
[9]  
Park G., 2000, Journal of Infrastructure Systems, V6, P153, DOI [10.1061/(ASCE)1076-0342(2000)6:4(153), DOI 10.1061/(ASCE)1076-0342(2000)6:4(153)]
[10]  
PEAIRS DM, 2001, P 3 INT WORKSH STRUC, P430